Download Print this page
Acer X223W Disassembly Instructions Manual

Acer X223W Disassembly Instructions Manual

Disassembly instructions
Hide thumbs Also See for X223W:

Advertisement

1. Firstly, before doing anything, you will need the following to hand,­
• Sellotape or some other form of tape 
• Scissors
• Medium philips screwdriver
• Small blade screwdriver
• Blunt knife
• Marker pen (fibre/felt tip)
• Clear, padded work surface. I used kitchen table with a travel rug beneath the 
table cloth. This is to avoid damage to the fascia and LCD components.
2. Step 1 – place the monitor face down on the work surface, remove the monitor stand by 
using the small bladed screw driver to remove  the two  plastic screw covers. You should use 
little to no force. Behind each cover are 2 x philips screws, remove both. The stand should no 
come free. I placed the screws back into the screw holes of the stand, and taped the screw 
covers behind them to hold the various pieces in place.
Rear of X223W with stand removed.
3. Step 2 – remove philips screw at centre bottom rear. Tape this to monitor stand foot.
4. Step 3 – Turn monitor over and starting at the bottom centre gently push rear of fascia case 
in and insert a blunt knife blade.  Gently work along base, then one side followed by the 
other. Take your time and AVOID the controls in the LCD monitor base. There are catches 
along the bottom and sides. These need to be gently released. When you've opened the sides 
and bottom, gently rotate the fascia up from the bottom, using the top as a hinge. At around 
15 – 20 degrees, you should be able to release the top catches too.
ACER X223W Disassembly Instructions.
Bob Felstead May 30, 2010

Advertisement

loading

Summary of Contents for Acer X223W

  • Page 1 ACER X223W Disassembly Instructions. Bob Felstead May 30, 2010 1. Firstly, before doing anything, you will need the following to hand,­ • Sellotape or some other form of tape  • Scissors • Medium philips screwdriver • Small blade screwdriver • Blunt knife • Marker pen (fibre/felt tip) • Clear, padded work surface. I used kitchen table with a travel rug beneath the  table cloth. This is to avoid damage to the fascia and LCD components. 2. Step 1 – place the monitor face down on the work surface, remove the monitor stand by  using the small bladed screw driver to remove  the two  plastic screw covers. You should use  little to no force. Behind each cover are 2 x philips screws, remove both. The stand should no  come free. I placed the screws back into the screw holes of the stand, and taped the screw  covers behind them to hold the various pieces in place. Rear of X223W with stand removed. 3. Step 2 – remove philips screw at centre bottom rear. Tape this to monitor stand foot. 4. Step 3 – Turn monitor over and starting at the bottom centre gently push rear of fascia case  in and insert a blunt knife blade.  Gently work along base, then one side followed by the  other. Take your time and AVOID the controls in the LCD monitor base. There are catches  along the bottom and sides. These need to be gently released. When you've opened the sides  and bottom, gently rotate the fascia up from the bottom, using the top as a hinge. At around  15 – 20 degrees, you should be able to release the top catches too.
  • Page 2 Use a blunt knife to open the LCD monitor screen. 5. Step 4 ­ Once you've removed the fascia there are 2 retaining screws holding the LCD to the  case at the rear. Remove them all, gently lift the LCD from the case rear and return the  screws to the unit so that you don't loose them.   Retaining screws for LCD unit at both sides.
  • Page 3 6. You're now left with the LCD screen, PSU etc. LCD & Protected PSU etc 7. Step 5 ­ Mark the illumination wires using the fibre tip pen – or however you wish to do so. Backlight connection, label and remove wires. 8. Step 6 ­ Remove the wires and the silver tape which holds the metal PSU case in place. You  will need to replace this when re­assembling the unit. Mark the position of the PSU case  with the fibre tip before removal.
  • Page 4 9. Step 7 ­ To remove the PSU, you will have to unstick the ribbon cable for the monitor  controls. Gently peel the ribbon cable off. DO NOT un­twist the ribbon cable. Simply lift it  up and lift the metal case. Take care – get someone to hold the case whilst you remove the  PSU. NOTE when re­assembling the position of the monitor controls. Peel back ribbon cable. NOTE control position 10. Step 8 –  There's a black insulating plastic film below the PSU. Remove this and keep it safe.  The PSU is held in place by 4 screws. The LCD driver is held in place by a single screw.  Remove ALL 5 screws, The whole assembly should now come out.
  • Page 5 Insulating sheet, PSU ­ left, LCD controller ­right 11. Step 9 ­Separate the 2 circuit boards by pulling them apart. The PSU may have a charge on  the large capacitor – SO TAKE CARE!!
  • Page 6 PSU ­ Left, LCD controller ­ Right 12. Step 10 – Repair PSU. Follow the guides shown by others on this site. The PSU is illustrated  below. I have listed the capacitors used and there values. You can check most of the  components with a multimeter. There are several fuses on the board, look at these first.  Secondly – diodes, thirdly, capacitors & resistors. Transistors, coils and voltage inverters last  of all. Capacitors Required for PSU Type Voltage micro farads Tolerance  Quantity 400v  35v 6.3v 1000 KNB1560 275vac 0.33 10% C>=0.1 uf PSU model:  FM­40A04­AAA Manufacturer: Asian Power DevicesRe­assembly reverse order as above. NOTE controls at  foot of screen. Whilst I'm not an electrical expert, you can email me for larger or original images  at bob.felstead@tiscali.co.uk. Good Luck!