Drying Mode; Heating Mode - Carrier 38LUVH025N Service Manual

Dc inverter hi-wall
Hide thumbs Also See for 38LUVH025N:
Table of Contents

Advertisement

8.5.5Turbo function(press the "TURBO" button on remote controller)
Elevate current frequency to a higher grade. Indoor fan turns to turbo speed.
After running for 30 minutes the machine will turn back to previous setting mode. Indoor fan operation rule. In
cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
Auto fan in cooling mode acts as follow:
8.5.6Condenser high temperature protection function(in cooling and drying mode)
If T3>60℃ for 5 seconds, compressor will stop immediately, and the machine will not resume until T3<52℃.

8.6 Drying mode

8.6.1
Indoor fan speed is fixed at breeze grade and can't be changed. The horizontal angle is the same as
in cooling mode.
8.6.2
Room over low temperature protection
In drying mode, if room temperature is lower than 10℃, compressor will stop and not resume until room
temperature climbs up to 12℃.
8.6.3
Evaporator anti-freezing protection, condenser high temperature protection and outdoor unit
frequency limit are valid, and they are the same as that in cooling mode.
8.6.4
Horizontal louver action is the same as that in cooling mode.

8.7 Heating mode

8.7.1 Indoor fan action :
Anti-cold-wind function.
If the compressor stops caused by room temperature rising, indoor fan will be forced to run 127 seconds with
breeze. During this period, anti-cold-wind is disabled. After this, anti-cold –wind function is available.
4.
0 3.
0 1.
5 1.
0
44
38
37
34
33
24
17
high
mediu
m
low
setting fan speed
low fan
breeze
super
breeze
fan stop
26

Hide quick links: