6.5.2.1 If TA﹥TS+1℃, the outdoor fan operates. After 15 seconds, the compressor operates.
6.5.2.2 The compressor is on, if TA≤TS, this compressor will stop. If the outdoor fan operates for 3
minutes at least, it will stop after delaying for 5 seconds.
6.5.3. When the unit is off, the compressor stops at first, and the indoor/outdoor fan will stop after
delaying for 5seconds. (If it operates at heating mode, the outdoor fan will be off delaying for 30
seconds).
6.5.4. Power management (for power management models)
Entering into the only-cooling mode, indoor fan motor operates immediately and keeps moving
for 30 minutes at lease. Compressor operates, and indoor fan motor keeps moving; Compressor
stops operation, indoor fan motor shuts off after a delay of 30 minutes.
6.5.5. The ION/TIMER functions are valid at the cooling mode.

6.6 Drying mode

6.6.1. The unit operates at drying mode. If TA>13℃, outdoor fan turns on, and then the compressor
operates after 15 seconds later.
Operation conditon
(TA-Ts) ℃
+1
0
Compressor off
Operation conditon
TA ℃
15
13
Compressor off
Compressor on
Compressor on
13

Advertisement

Table of Contents
loading

Table of Contents