Mains Electricity Connection - CDA hn6410 Manual For Installation, Use And Maintenance

Table of Contents

Advertisement

Mains Electricity Connection

Warning! this appliance must be earthed
We recommend that the appliance is connected by a qualified
electrician, who is a member of the N.I.C.E.I.C. and who will comply
with the I.E.T. and local regulations.
This hob is intended to be connected to permanent, fixing wiring and
dependent on the power configuration is intended to be connected
to a 13A supply or connected via a 13A plug. The table below shows
the recommended size of cable and the fuse that will be required for
each power configuration mode.
Power configuration mode
2.8kW
3.5kW
6.0kW
7.2kW
9
The following diagram shows the main connection terminal block:
Terminal connections:
1, 2 &3: Live (linked)
4: Neutral
: Earth
2.8kW mode
When the hob is configured in 2.8kW
mode it can be connected via a
standard 13A switched fused spur.
Mains cable size (CSA, mm2)
1.5
1.5
2.5 - 4.0
2.5 - 4.0
fast frying steaks
Fuse protection required
13
16
25
32
Fig.6
21