5. Press the start pad or set the timer and with the
magnetron oscillating, measure the leakage by
holding the probe perpendicular to the surface
being measured. Move it along the edges of the
door, the display panel, and the cover at a very
slow speed no faster than 1 inch/sec (2.5cm/sec).
Leakage reading for a fully assembled oven with door normally closed should be
2
less than 2mW/cm
Leakage reading for a fully assembled oven [Before the latch switch (primary) is
interrupted] while pulling the door should be less than 2mW/cm 2.
Leakage reading for an oven with the outer panel removed should be less than
2
5mW/cm
.
2
(1mW/cm
for Canada).