Toyotomi TPN A128 IVP Service Manual page 54

Table of Contents

Advertisement

Safety
Electricity power is still kept in capacitors even the power supply is shut off. Do not forget to discharge the electricity
power in capacitor.
Connect discharge resistance (approx.100Ω 40W) or soldering iron (plug) between +, - terminals of the electrolytic
capacitor on the contrary side of the outdoor PCB.
Note: The picture above is only for reference. The plug of your side may be different.
Main parts check
1.
Temperature sensor checking
Disconnect the temperature sensor from PCB, measure the resistance value with a tester.
Electrolytic Capacitors
(HIGH VOLTAGE! CAUTION!)
54

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents