Refrigerant Cycle Diagram - Toyotomi TPN A128 IVP Service Manual

Table of Contents

Advertisement

4. Refrigerant Cycle Diagram

INDOOR
HEAT
EXCHANGE
(EVAPORATOR)
LIQUID SIDE
2-WAY VALVE
GAS SIDE
3-WAY VALVE
ACCUMULATOR
10
OUTDOOR
CHECK VALVE
(Heating Model only)
CAPILIARY TUBE
HEAT
EXCHANGE
(CONDENSER)
REVERSING VALVE
(Heating Model only)
COMPRESSOR
COOLING
HEATING

Hide quick links: