Fill Funnel

The fi ll funnel is mounted on the right side of the
tub. Its purpose is to provide a method of supplying
water for the wash and rinse cycles. The air gap
prevents the siphoning of wash water from fl owing
back into the water supply system, should the water
pressure drop to less than atmospheric pressure.
The fi ll funnel also allows air into the tub to permit
airfl ow for drying dishware.
To remove the fi ll funnel:
1. Disconnect power.
2. Access the fi ll funnel by carefully pulling the
dishwasher out from its installation.
3. Open the dishwasher door.
4. Rotate the fi ll funnel cap counterclockwise and
remove it from the fi ll funnel.
Fill Funnel Cap
5. Loosen the clamp and disconnect the fi ll funnel
hose from the fi ll funnel.
Clamp
Hose
Fill Funnel
Note: Upon assembly, ensure the fi ll funnel gasket is
placed over the fi ll funnel threads.
– 23 –
Gasket