Operating The Unit - Baxi Bermuda SP3 Renewal Operating Instructions Manual

Fireside gas central heating unit
Hide thumbs Also See for Bermuda SP3 Renewal:
Table of Contents

Advertisement

Introduction
Your Baxi Bermuda SP3 or VP3 is a
central heating boiler combined with
a gas fire. Normally the fire will heat
the room in which it is situated and
the boiler will provide heating for the
rest of the house and also domestic
hot water if required. The boiler and
fire are independently controlled.
The boiler may be controlled by an
external programmer or clock control
(see separate instructions with the
clock controller used). The fire is
controlled by the knob which is
located on the right hand side of the
outer case.
Important Notice
The
Bermuda
VP3
appliance is for use on PROPANE
GAS ONLY and cannot be used on
any other gas. Propane appliances
can be converted to operate on
Natural Gas if required at a later
date. Consult your Installer
WARNING
Bermuda SP3 and VP3 Renewal
Firefronts MUST NEVER be fitted as
independent gas fires without the
boiler.
Important Information
This product uses a fuel effect coal
bed containing Refractory Ceramic
Fibres (R.C.F.) which are man-made
vitreous silicate fibres. Excessive
exposure to these materials may
cause temporary irritation to eyes,
skin and respiratory tract. Care must
be taken when handling these
articles to ensure the release of dust
or fibres is kept to a minimum. Refer
to the section Cleaning the Fire.
NOTE: When your Bermuda is first used it is
possible that certain smells may be emitted.
These smells will quickly clear with use. As
the fire is used more and more, the bright
finished metal around the coal bed will begin
to darken. This is perfectly normal and will
enhance the realism of the coal and flame
effect.
Most heating appliances generate warm air
convection currents and transfer heat to any
wall surface against which they are situated.
Some soft wall furnishings (such as blown
vinyl wallpapers) may not be suitable for use
where they are subjected to temperatures
above normal room levels. The manufacturers
advice should be sought before using this
type of wall covering adjacent to any heating
appliance. The likelihood of wall staining from
convected air currents will be increased in
environments where high levels of tobacco
smoke or other contaminants exist.
Pilot Viewing Window
Indicator Light
Electronic Controls Boiler
(51/5)
Controls Access Panel
BERMUDA SP3
Propane
Fender Front
BERMUDA VP3
Pilot Viewing Window
(401 Boiler)
Plug &
Socket
Igniter Button
Manual Controls Boiler
(401 & 552 & 553 Propane)
Pilot ViewingWindow(Series 4)
Igniter
Button
Thermostat Knob
Manual Controls Boiler
(45/3M, 57/3M, 45/4M & 57/4M)
Pilot Indicator Light
Boiler Lockout Light
(Series 4)
Electronic Controls Boiler
Thermostat
Knob
(45/3E, 57/3E, 45/4E & 57/4E)

OPERATING THE UNIT

Boiler
Controls
Boiler Controls
Pilot Viewing Window
(552 Boiler & 553
Propane)
Service
Tap
Grey Push
Thermostat
Button
Knob
Service Tap
Pilot Viewing
Grey Push
Mirror(Series 3)
Button
Service
Thermostat
Tap
Knob
page 4
1
Ensure that the fire is cold.
(Bermuda SP3) Open the controls
access panel by pushing inward at
the bottom. Lift the panel and pull
forward to fix in the open position.
(Bermuda VP3) Remove the fender
front at the bottom of the fire by
pulling forward.
2
Turn the boiler thermostat knob to
the off position (
).
Manual
Electronic
Controls
Controls
Boiler
Boiler
Turn on the main gas and
3
electricity
supplies
appliance.
4
TO LIGHT THE BOILER PILOT:
(Manual Controls Boiler) Hold in
the grey push button on the gas
control valve. Looking through the
pilot viewing window or mirror: Press
the igniter button and release. Repeat
until the pilot lights.Continue to hold in
the grey push button for a further 15
seconds. The pilot should stay alight.
NOTE:
If the pilot fails to remain alight or
is extinguished at any time, wait at least 3
minutes then repeat step 4. Once the pilot
is alight it may be left on permanently.
Grey Push Button
Igniter Button
5
TO
LIGHT
THE
(Manual
Controls
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. Turn the boiler
thermostat knob to the desired
position.
6
TO
LIGHT
THE
(Electronic Controls Boiler)
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. To operate the pilot
turn the thermostat knob to the
desired position. The indicator light
on the control box will illuminate once
the pilot is lit. The burner will also
light shortly after the pilot has been
established.
To adjust the boiler temperature:
Turn the boiler thermostat knob
clockwise to the required setting. The
optimum boiler thermostat setting
depends upon type of system,
external
controls
requirements. Your Installer will be
able to advise you on this matter.
If the boiler cannot be lit by the
above method consult your
Service Engineer.
to
the
BOILER:
Boiler)
BOILER:
and
your