Control Board Section "A - A.O. Smith PHPT-60 Service Handbook

Residential hybrid electric heat pump water heater
Table of Contents

Advertisement

Figure 6
CN201
FUS201
CN207
CN 201 Line Power:
Pin 1 - Control board power wire L1 (240VAC)
Pin 2 - Control board power wire L2 (240VAC)
Pin 3 - Not used
Pin 4 - Control board power wire ground
CN 202 ECO Bottom:
Pin 1 - Connect to lower heating element
Pin 2 - Connect to L1 behind ECO switch
CN 206 Compressor:
Pin 1 - Compressor power L1
Pin 2 - Unused
Pin 3 - Unused
Pin 4 - Compressor power L2
CN 207 Fan Low/high:
Pin 1 - Fan power L1
Pin 2 - Unused
Pin 3 - Fan power
FUS 201:
Fuse 201 (3 Amp, 250V, slow blow) fuses the L1 power leg coming to the Control Board
FUS 202:
Fuse 202 (3 Amp, 250V, slow blow) fuses the L2 power leg coming to the Control Board
Section "A" of Control Board
Section "A"
FUS202
CN202
CN206
15