Specifications Of Electrical Parts - Carrier 42NQV025H Service Manual

Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
Parts name
No.
42NQV025H, 42NQV035H,
Fan motor
42NQV035M
1
(for indoor)
42NQV045H, 42NQV045M
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (6P)
38NYV025H,38NYV035M
8
Compressor
38NYV035H,38NYV045M
38NYV045H
9
COIL FOR P.M.V.
10
Coil for 4-way valve
11
Compressor thermo
Type
MMF-240-20-4B
AC240/220V, 20W
DC 340V, 30W
ICF-340-30-2
( − )
10k
(
)
10kΩ at 25°C
MP24Z3T
Output (Rated) 1W, 16 poles, DC12V
Model name
CH-57
L = 10mH, 16A
ICF-140-43-4R
DC140V, 43W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C)
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
10kΩ (25°C)
30A, AC600V
DA89X1C-23FZ
3-phases 4-poles 750W
DA111A1F-20F1
C12A01A
DC12V
VHV
AC220-240V
PW-2AL
OFF : 125±4°C, ON : 90±5°C
− 20 −
FILE NO.SVM-07013
Specifications
at 25°C
Rating

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents