IDEAL Esprit eco 24 User Manual

Wall mounted, room sealed, condensing combination boiler
Hide thumbs Also See for Esprit eco 24:

Advertisement

USERS GUIDE

Esprit eco
24, 30
For installation guide see reverse of book
When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL Esprit eco 24

  • Page 1: Users Guide

    When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
  • Page 2: To Light The Boiler

    Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500. Ideal is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 3: Control Of Water Temperature

    Weather Compensation Operation Winter conditions - i.e. Ch and DhW required. When the Weather Compensation option is fitted to the system then the CH Temperature Control (C) becomes a method of Ensure the mode knob control (A) is set to winter ( controlling room temperature.
  • Page 4: Loss Of System Water Pressure

    Loss of system water pressure Condensate Drain The gauge (H) indicates the central heating system pressure. This appliance is fitted with a siphonic condensate trap system If the pressure is seen to fall below the original installation that reduces the risk of the appliance condensate from freezing. pressure of 1-2 bar over a period of time then a water leak may However should the condensate pipe to this appliance freeze, be indicated.
  • Page 5: Programming The Timer

    MEChaNICaL 24 hOUR TIMER pROgRaMMINg ThE TIMER 1. Decide what times you would like the timeswitch to switch Timer Control Permanently ON ON and OFF. Permanently OFF Time & Control 2. Push segments towards the programme ring for an OFF Indicator period and push away from ring for an ON period.
  • Page 6: Troubleshooting

    See boiler “Operation Modes” section. If ‘0’ is displayed then and “Fault Codes” section contact Ideal Boilers if your appliance is under warranty or a Gas Safe Registered Engineer, Check the time settings on the in IE a Registered Gas Installer...
  • Page 7: Operation Modes

    OpERaTION MODEs DEsCRIpTION DIspLay CODE ON BOILER The boiler is in standby mode awaiting either a central heating call or hot water demand. The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler. The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler.
  • Page 8: Fault Codes

    5 Boiler Resets in 15 minutes 1. Turn power off and on at the fused spur. 2. If the boiler fails to operate please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period.

Table of Contents