Summary of Contents for IDEAL 36

  • Page 1 rangeguide Commercial & Industrial Boilers & Radiators www.idealcommercialboilers.com...
  • Page 2: Table Of Contents

    contents Boilers Condensing icos HE plus II xtra Concord CXC GT Condenser Gas Atmospheric Concord CXA/H S/H Concord Modular Concord CXSi/H Concord ES/H High Efficiency Super Series 4 Super Plus Pressure Jet Buccaneer GTE Falcon GTS Harrier GTE Viceroy GT Viscount GTE Vanguard L Radiators...
  • Page 3 Ideal launched the xtra maintains Ideal’s position as the The recent addition of the market leading supplier in the Commercial and Industrial boiler sector. The Commercial Heating Team As industry leaders Ideal Boilers and Stelrad Radiators are committed to ensuring that all products are engineered to the highest standards.
  • Page 4: Condensing

    Easy to install and service • Modulating output down to 10.4kW • Wide range of flue options • Optional remotely mountable user controls General Data icos HE (30 + 36) Model Boiler Output (condensing) 50/30˚C Boiler Output (non-condensing) 80/60˚C Height Width Depth...
  • Page 5 Remote indication kit ✓ Hours run meter(s) ✓ BMS (0-10V) kit ✓ Pump kit ✓ Multi boiler frame and header kits ✓ *Provided as standard W80P 21.3 - 82.7 20.7 - 80.0 19.5 - 78.2 100/150 ✓...
  • Page 6: Plus Ii

    • Optional flue and system connections for fast installations • Meets Building Regulations 2006 (Part L2) • plus II (90 - 310) General Data Model Boiler output (condensing) 50/30˚C Boiler output (non-condensing) 80/60˚C Height Width Depth Flow/Return Connections (BSP) Gas Inlet (BSP)
  • Page 7: Xtra

    311.6 390.8 469.0 547.2 1200 1200 1200 1200 1327 1004 1326 1326 1326 R2” R2” R1” 27.2 35.0 36.8 48.0 54.4 1000 1000 1000 1000 xtra 80 - 280 320 - 560 ✓ ✓ ✓ ✓ ✓ ✓ ✓ Standard...
  • Page 8: Concord Cxc

    Concord CXC • Natural gas fired condensing boiler • Meets Building Regulations 2006 (Part L2) • Fully condensing high efficiency 85% at 80˚C, 93% at 60˚C flow • Compact space saving design • Full automatic ignition • Advanced electronic controls...
  • Page 9: Gt Condenser

    Depth (mm) (over optional fan) 1156 Flue Size (mm) The addition of a GT Condenser to the boiler can provide up to 16% more heat by cooling the flue gases to gain both sensible and latent heat from condensation. The lower the system return temperature being fed into the Condenser the more the gain.
  • Page 10: Gas Atmospheric

    Approx Dry Weight (kg) Front (mm) Boiler Clearances Back (mm) Sides (mm) 50 Option Kits Boiler Volt free contacts, boiler run, overheat & lockout Down draft thermostat kit Header kits (available from merchants) Propane models 40 - 120kW 60/H 70/H...
  • Page 11: Concord Modular

    Multiple installation outputs from 80-720kW • All servicing and maintenance from the front of boilers • Large clean-out cover for full access to flueways • Standard boiler width: 600mm • Factory assembled and tested units • Sequencer control kit available •...
  • Page 12: Concord Cxsi/H

    Maximum Working Pressure (bar) Water Content (L) Approx Dry Weight (kg) Front (mm) Boiler Clearances Back (mm) Side (mm) Option Kits Boiler Volt free contacts, alarm & boiler run conditions 110 - 180kW 110/H 120/H 140/H 1000 1107 1107 1230 1036...
  • Page 13: Concord Es/H

    Maximum Working Pressure (bar) Water Content (L) Approx Dry Weight (kg) Front (mm) Back (measured from rear edge of jacket) (mm) Boiler Clearances At sides Water connection side (RH or LH) (mm) At sides Non connection side (RH or LH) (mm) Option Kits...
  • Page 14: High Efficiency

    Front (mm) Back (mm) Boiler Clearances Left (mm) Right (mm) 450 Option Kits Boiler Water flow switch for boiler protection in the event of pump failure External sequencer control kit Module blanking off pack 50 - 600kW 1487 1487 1967...
  • Page 15: Super Plus

    Back (mm) Boiler Clearances Left (mm) Right (mm) Option Kits Boiler Water flow switch for boiler protection in the event of pump failure Remote indication of boiler on, lockout and overheat for each module Module blanking off pack 300/3 300/3A...
  • Page 16: Pressure Jet

    Depth (mm) Flow/Return Connections (BSP) Maximum Working Pressure (bar) Flue Size (mm) Water Content (L) 24.5 Approx Dry Weight (kg) Front Back (mm) Boiler Left (mm) Clearances Right (mm) Option Kits Boiler DHW sensor 21 - 39kW GTE 5 27 - 33 30.0...
  • Page 17: Falcon Gts

    Height Width Depth Flow/Return Connections (BSP) Maximum Working Pressure (bar) Flue Size (mm) Water Content (L) Approx Dry Weight (kg) Front (mm) Back (mm) Boiler Clearances Left (mm) Right (mm) Option Kits Boiler DHW sensor Model GTS 5 GTS 6...
  • Page 18: Harrier Gte

    Flow/Return Connections (DN flange) Flue Size (mm) Maximum Working Pressure (bar) Water Content (L) Approx Dry Weight (kg) Front (mm) Back (mm) Boiler Clearances Side - non hinge (mm) Side - door hinge (mm) Option Kits Boiler Hours run meter(s)
  • Page 19: Viceroy Gt

    Flue Size (mm) Maximum Working Pressure (bar) Water Content (L) Approx Dry Weight (kg) 1941 Front (mm) 1500 Back (mm) Boiler Clearances Left (mm) Right (mm) Option Kits Boiler Hours run meter(s) De Luxe control panel (High / Low operation)
  • Page 20: Viscount Gte

    Maximum Working Pressure (bar) Water Content (L) Approx Dry Weight (kg) 3218 3430 Front (mm) Back (mm) Boiler Clearances Side - non hinge (mm) Right (mm) Option Kits Boiler Hours run meter(s) De Luxe control panel (High / Low operation)
  • Page 21: Vanguard L

    1122 1122 1352 1541 1606 1801 2113 1989 2184 2379 2346 1040 1047 1341 1447 1553 1821 Same length as boiler 200 + burner length 1320 1570 1850 2200 2650 3000 3500 1320 1570 1850 2200 2650 3000 3500 1622...
  • Page 22: Stelrad Radiators

    Stelrad Radiators Stelrad Radiators Stelrad is the UK market leader in central heating radiators, offering the widest range, and in more sizes, than any other manufacturer. Our highly advanced production and distribution facility in Mexborough, UK, produces over 2.5 million steel panel radiators a year, for both Domestic and Commercial markets.
  • Page 23 quality, choice & style Ladder & Mini Ladder • 28 Models • Heights 698 - 1800mm • Lengths 400, 500 & 600mm • Output 240 - 1022 watts • Types Straight/Curved - White/Chrome • Cost effective • Adds elegance Vertex •...
  • Page 24: Traditional

    Traditional Data & Dimensions Height Length Output Watts at Δ T50 (mm) (mm) 1000 1500 1164 2000 1034 1552 2500 1293 1940 3000 1551 2328 1000 1106 1100 1217 1200 1327 1400 1075 1548 1600 1229 1770 1800 1382 1991 2000 1536 2212...
  • Page 25: Compact

    Data & Dimensions Height Length Output Watts at Δ T50 (mm) (mm) 1000 1500 1118 1473 2000 1018 1490 1964 2500 1273 1863 2455 3000 1527 2235 2946 1097 1234 1000 1055 1371 1100 1161 1508 1200 1266 1645 1400 1058 1477 1919...
  • Page 26: Low Surface Temperature

    low surface temperature Data & Dimensions Height Emitter Length (mm) Height (mm) (mm) 1160 1360 1560 1760 1960 1160 1360 1560 1015 1760 1160 1960 1305 1160 1360 1096 1560 1278 1760 1461 1960 1643 LST Standard Output Watts at Δ T50 1044 1218 1136...
  • Page 27: Lst Plus

    Data & Dimensions Model Height Height Emitter Length Emitter (mm) Height (mm) Length inc Kick Grille (mm) (mm) (mm) 1050 1250 1000 1450 1200 1650 1400 1850 1600 2050 1800 1050 1250 1000 1450 1200 1650 1400 1850 1600 1058 2050 1800 1190...
  • Page 28: Specifier Range

    specifier range Data & Dimensions - Style Height Length Output Watts at Δ T50 (mm) (mm) 1000 1400 1217 2000 1738 1029 1000 1286 1200 1543 1400 1016 1800 1600 1162 2058 1800 1307 2315 2000 1452 2572 1194 1000 1492 1200 1016...
  • Page 29: Planar

    Data & Dimensions Height Length Output Watts at Δ T50 (mm) (mm) 1000 1400 2000 1000 1200 1400 1600 1002 1800 1127 2000 1252 1000 1200 1400 1084 1600 1238 1800 1393 2000 1548 1000 1200 1093 1400 1275 1600 1458 1800 1640...
  • Page 30: Concord

    data & dimensions Data & Dimensions - Plane Height Length Elements (mm) (mm) 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 1000 1100 1200 1400 1600 1800...
  • Page 31: Radiator Options

    radiator options Valves Stelrad can offer a range of luxury valves to complement our design products. Extension Pieces 20/30 and 40mm extension pieces are available to help bridge gaps on replacement installations. Continental Brackets If it is extra security you need, continental brackets clean up the top and bottom seam offering greater...
  • Page 32 Range/7/07 © 2007 Ideal Boilers Limited 100 150 200 340 511 682 40-120 40-120 110-180 140-380 80-720 50-600 200-600 30-36 45-80 48-116 90-310 80-560 21-39 40-100 105-330 Approval These appliances are certified to G.A.D. 90/396 and B.E.D. 92/42 safety and performance Directives for gas boilers.

This manual is also suitable for:

30F180F140F220F270F310 ... Show all