Miele DA 5190 W Operating And Installation Instructions
Miele DA 5190 W Operating And Installation Instructions

Miele DA 5190 W Operating And Installation Instructions

Ventilation system

Advertisement

Operating and Installation
Instructions
Ventilation System
DA 5190 W
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 787 390

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 5190 W

  • Page 1 Operating and Installation Instructions Ventilation System DA 5190 W en - US, CA To prevent accidents and appliance damage, read these instructions before installation or use. M.-Nr. 07 787 390...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS....... . . 3 Functional description ..........7 Guide to the Ventilation System .
  • Page 3: Important Safety Instructions

    Use this appliance only in the manner intended by the manufacturer. Read these instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the Ventilation System. appliance, switch power off at the...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance to the power supply make sure that the ,WARNING voltage and frequency listed on the data plate correspond with the TO REDUCE THE RISK OF A household electrical supply. COOKTOP GREASE FIRE: This data must correspond to prevent appliance damage.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS ,WARNING Do not allow children to play with or operate the appliance or its controls. TO REDUCE THE RISK OF Supervise its use by the elderly or INJURY TO PERSONS IN THE infirm. EVENT OF A COOKTOP Always turn on the hood when using GREASE FIRE, OBSERVE THE the cooktop to prevent damage from...
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Installation g) Do not install this hood over cooktops that burn solid fuel. ,WARNING h) Provided a larger distance is not TO REDUCE THE RISK OF given by the manufacturer of the FIRE, ELECTRIC SHOCK, OR cooktop, follow the minimum safety distances between a cooktop and the INJURY TO PERSONS, bottom of the hood given in the...
  • Page 7: Functional Description

    The active charcoal filter and the installation kit may be purchased from room air can occur. your Miele. When the hood is turned on, the air pressure of the exhaust fan auto- Before using the hood in...
  • Page 8: Guide To The Ventilation System

    Guide to the Ventilation System...
  • Page 9: Guide To The Ventilation System

    Guide to the Ventilation System a Chimney extension l Grease and charcoal filter button b Chimney The filter indicator light lights red when the grease filter needs to be cleaned. c Canopy The indicator light lights blue when the active charcoal filter needs to be d Overhead lighting changed.
  • Page 10: Operation

    Operation Turning on the fan Automatically switching back the intensive power level The intensive level "4" can be programmed to automatically switch back to level "3" after 10 minutes. ^ Turn the fan and the lights off. ^ Press the On/Off button. Selecting the power level ^ Press and hold the Delayed Shut Down button at the same time for 10...
  • Page 11 Operation Fan performance The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this If the power level indicators "1" and "4" value. flash, the automatic switch back is not Level 1 operates at 40% capacity activated.
  • Page 12: Delayed Shut Down

    Operation Delayed Shut Down Turning off the fan If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue ^ Press the On/Off button to turn the running for either 5 or 15 minutes.
  • Page 13: Turning The Lighting On/Off

    Operation Turning the lighting on/off Dimming the lighting The overhead lighting can be turned on The brightness of the lighting can be and off independently of the fan. adjusted. ^ While the lighting is turned on, press and hold the light button. The lighting will dim until the button is released.
  • Page 14: Grease Filter Timer

    Operation Grease filter timer Checking the filter timer A timer monitors the hours of fan To check the percentage of time operation. The indicator for the already used: grease/charcoal filter will light red after 30 hours of operation or the preselected time.
  • Page 15 Operation Reprogramming the grease filter timer The grease filter timer is preset to 30 hours. This time can be lengthened or The lit "–/+" indicator shows the shortened to 20, 30, 40 or 50 hours. programmed time: – A time of 20 hours should be 1st indicator from the left = 20 hours programmed in kitchens with...
  • Page 16 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and cannot The lit indicator shows the programmed be used to exhaust fumes. time: The charcoal filter timer is not preset. 1st indicator from the left = 120 hours Before using the hood in recirculation 2nd indicator from the left = 180 hours...
  • Page 17: Cleaning And Care

    Cleaning and Care ,WARNING Avoid: TO REDUCE THE RISK OF – cleaning agents containing soda, FIRE, ELECTRIC SHOCK, OR acids, chlorides or thinners, INJURY TO PERSONS, – abrasive cleaning agents OBSERVE THE FOLLOWING: e.g. powder or cream cleansers, – abrasive sponges, e.g. pot scourers Before cleaning or servicing the or sponges which have been hood, disconnect it from the power...
  • Page 18: Grease Filter

    Cleaning and Care Grease filter Removing the grease filter The reusable metal grease filter removes solid particles from the vented kitchen air (grease, dust, etc). The grease filter should be cleaned every 3 - 4 weeks or whenever the grease filter indicator lights red. ^ To remove the grease filter pull the locking clip forward.
  • Page 19 Use a wash program with a max. the grease filter button for 3 seconds temperature of 150°F (65°C). In a to reset the timer. Miele dishwasher use the "Normal" The indicator light will go out. program. ^ If the grease filter is cleaned before Use the recommended amount of dishwasher detergent.
  • Page 20: Active Charcoal Filter

    Replacement active charcoal filters can be ordered from Miele. ^ After replacing the charcoal filter, press the grease/charcoal filter ^ Remove the grease filter to access button twice and hold for about the charcoal filter.
  • Page 21: Changing The Light Bulbs

    Cleaning and Care Changing the light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands.
  • Page 22: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 23: Installation Instructions

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 25: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 26: Appliance Dimensions

    Appliance dimensions 1) Air extraction mode 4) and 5) Installation area Wall/ceiling area respectively for vent 2) Recirculation mode hole and outlet installation. 3) Recirculation vent installed upwards For recirculation mode only 4) and only outlet installation.
  • Page 27 Appliance dimensions 4) and 5) Standard unit height H Cut-out area in wall or ceiling for Air extraction ... . 28" - 40 " entrance of 6" (150 mm) ....(710 - 1025 mm) ductwork or 5"...
  • Page 28 Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: Miele Cooktops Non-Miele Cooktops Electric Cooktops 24"...
  • Page 29: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the lower retaining ^ Mark a vertical cutting line along the plate.
  • Page 30: Installation

    Installation...
  • Page 31 Installation a 3 protective shields to prevent scratches to the chimney during installation. 6 large headed screws 5 x 40 mm b 1 vent collar for securing the retaining plates and the for use with 6" (150 mm) exhaust canopy ducting (S8 wall anchors included in the c 1 reducing collar...
  • Page 32: Installation

    Installation Protective film Dismantling The casing is covered with a protective If the hood needs to be disassembled, film to prevent scratching during follow the instructions on the transport. "Installation diagram" in the reverse order. ^ Peel off the film before installing the casing parts.
  • Page 33: Air Extraction

    Air extraction Exhaust ducting and connections WARNING Use smooth or flexible pipework made from approved non-flammable Danger of toxic fumes. materials for exhaust ducting. Gas cooking appliances release To achieve the most efficient air extraction and quietest noise levels, carbon monoxide that can be consider the following: harmful or fatal if inhaled.
  • Page 34: Condensate Trap

    Air extraction Condensate trap optional accessory In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur. This optional accessory is available for ducts 5" (125 mm) and 6" (150 mm) in diameter. –...
  • Page 35: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. ,WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 36: Technical Data

    Technical data Maximum load ....430 W Fan ..... . 350 W Overhead lighting .
  • Page 40 Alteration rights reserved / 1711 M.-Nr. 07 787 390 / 02 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.

Table of Contents