Note: If DM100 Series Doors are to be installed onto this
fi replace at any time, we recommend they be installed at
the same time as refractory to avoid the need to remove
refractory at a later date.
Remove smoke shield by removing fi ve screws (starting
from one side: remove two, skip one, remove one, skip
one, remove two). See Figures 4.13 and 4.14.
Figure 4.13 Removing Smoke Shield
Front Face
Skip
Remove these screws.
Figure 4.14 Removing Smoke Shield
Position the refractory. Position the bottom of the back
refractory to the back of the fi replace and center from
side to side. See Figure 4.15. Be sure to position it so the
retainer notch is at the top.
Figure 4.15 Installing Back Refractory
16
Smoke Shield
Skip
Heat & Glo • EXCLAIM-50 • 4013-041 Rev Q • 06/07
Fasten in place with the refractory retainer and screws
provided. See Figure 4.6.
Figure 4.16 Attaching Back Refractory
Note:
To ensure proper installation, gas knockouts in the side
refractory should be positioned towards back of fi replace. See
Figure 4.15.
Place side refractory into fi replace. Position towards
front of fi replace and slide to the rear. See Figures 4.17
and 4.18.
Figure 4.17 Installing Side Refractory
Figure 4.18 Side Refractory In