• High Efficiency
Impack performance is among the highest
in the industry.
• Climatuff
®
Compressor
Protection against chemical, electrical, and
mechanical stresses are built in for
efficiency and a longer life. The compressor
is backed by a 5-year limited warranty, with
an optional warranty for 5 more years.
• Time Defrost Control
This is an electronic, time initiated, tempera-
ture terminated defrost system that offers a
choice of 50, 70, or 90 minute cycles. The
time override limits the defrost cycle to 10
minutes.
• Convertibility
Impack units are easily converted from
horizontal to downflow with the removal of
one screw from each panel. Accordingly, the
need to stock both dedicated horizontal and
dedicated downflow models has been
eliminated.
• Installation
The ease of installation and application
flexibility exhibited through the design
reduce both field time and material.
• Application
The low profile horizontal duct take-offs
eliminate the need for expensive transition
ducts in crawl space applications.
• Commonality
The common cabinet among the TCC's,
WCC's, and YCC's minimizes both the
training of sales and service personnel and
replacement parts inventory.
• Flexibility
A single curb fits the entire Impack line from
1.5 tons through 5 tons thereby providing
great installation flexibility on shopping
malls, factories, schools, and other
commercial buildings where a mix-match of
tonnages and utilities is desired.
Features and
Benefits

Standard Equipment

• Water-Shed™ Base
Superior water integrity is accomplished
with the Water-Shed™ base pan having
elevated downflow openings and a perim-
eter channel that prevents water from
draining into the ductwork.
• Easy Access
All electrical components can be diagnosed
and replaced with the removal of one panel
that is attached with two screws.
• Service
All wiring is both numbered and color coded
thereby reducing training and servicing
costs related to circuit tracing and compo-
nents replacements.
• Maintenance
A plug on the outdoor fan motor allows the
top cover to be removed completely without
the hassle of cumbersome wires. The
unique service orifice ring allows the indoor
fan motor/blower to be removed as a unit.
• Plate Fin Coil
Refrigeration coils are built with internally
enhanced copper tubing for high efficiency
with less coil area.
• Shipping
Unit dimensions were carefully selected to
provide an attractive aspect ratio and for
shipping and handling considerations.
• Good Neighbor
Most units can be installed flush with the
residence or building thereby minimizing the
ground space required. Blankets of
insulation reduce blower noise and energy
losses to the outside environments.
• Rooftop Mounting
The cabinets are physically smaller than
most competitive models. This means less
intrusive installations on residential rooftops
where aesthetics are critical.
4
• Handling
The three-way wooden skid allows for easy
loading between the wheel wells on pickup
trucks for transporting to job sites.
• Structure
The units are lighter weight through the use
of high technology components thereby
reducing mounting structure requirements
and difficulty when handling.
• Duct Flanges
Only Impack has downflow duct flanges for
duct attachments that preserve the built-in
water integrity.
• Corrosion
The drain pan is engineered material and
eliminates the need for coatings and sealers
to prevent sweating and corrosion. The
heavy gauge, zinc-coated steel cabinet has
a weather resistant enamel finish that stays
attractive and protects your investment for
years.
• Low Ambient Control
Zero degree ambient cooling is accom-
plished with two kits. One for low cost
installations when full tonnage is not
needed. The other kit maintains head
pressure and full capacity at zero degrees.
• Quality and Reliability Testing
We perform a 100% coil leak test at the
factory. The evaporator and condenser
coils are leak tested at the factory. The
evaporator and condenser coils are leak
tested at 200 psig and pressure tested to
450 psig respectively. In addition the Impack
designs were rigorously rain
tested at the factory to ensure water
integrity. Shipping tests are performed to
determine packaging requirements. Factory
shake and drop tests are used as part of
the package design process to help assure
that the unit will arrive at the job site in top
condition. Additionally, all components are
inspected at the point of final assembly.
Substandard parts and components are
identified and rejected immediately. Every
unit receives a 100% run test before leaving
the production line to make sure it lives up
®
to rigorous Trane
requirements. We at
Trane test our designs at our factory and not
on our customers!
IPB-99-7-EN-10-6-99