Trane WCY024G1 Installation, Operation & Maintenance Manual
Trane WCY024G1 Installation, Operation & Maintenance Manual

Trane WCY024G1 Installation, Operation & Maintenance Manual

Single package heat pump 13-14 seer convertible 2 - 5 ton

Advertisement

INSTALLATION
OPERATION
MAINTENANCE
ALL phases of this installation must comply with
NATIONAL, STATE AND LOCAL CODES
Model:
WCY024G1
WCY030G1
WCY036G1
WCY042G1
WCY048G1
WCY060G1
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.
WARNING:
All phases of this installation must comply with the NATIONAL,
STATE & LOCAL CODES. In the absence of local codes, the
installation must conform with National Electric Code -- ANSI/
NFPA 70 or "LATEST REVISION."
Since The Trane Companyhas a policy of continuous product and product data
improvement, it reserves the right to change design and specification without notice.
© 2002 American Standard Inc. All rights reserved
BAYLIFT002A
LIFTING LUG KIT
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
Single Package Heat Pump
13-14 SEER Convertible
2 - 5 Ton
NOTICE
Warnings and Cautions appear at appro-
priate locations throughout this manual.
Read these carefully.
Indicates a potentially haz-
WARNING:
ardous situation which, if not avoided, could
result in death or serious injury.
CAUTION:
Indicates a potentially haz-
ardous situation which, if not avoided, may
result in minor or moderate injury. It may also
be used to alert against unsafe practices
and where property-damage-only accidents
could occur.
WCY-IOM-1D
18-BB33D8-5
07/02

Advertisement

Table of Contents
loading

Summary of Contents for Trane WCY024G1

  • Page 1 National Electric Code -- ANSI/ NFPA 70 or "LATEST REVISION." Since The Trane Companyhas a policy of continuous product and product data improvement, it reserves the right to change design and specification without notice. © 2002 American Standard Inc. All rights reserved...
  • Page 2: General Information

    IMPORTANT: Read this entire manual before beginning instal- lation procedures. SAFETY NOTICE. THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSESSING ADEQUATE BACK- GROUNDS OF ELECTRICAL AND MECHANICAL EXPERI- ENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI- TIONING PRODUCT MAY RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE.
  • Page 3 TYPICAL ROOFTOP INSTALLATION WITH BAYCURB030A SEE NOTE 1 ROOF INSULATION ROOF DECK FIELD SUPPLIED RIGID INSULATION NOTE 1: The WCY036-042G Models extend out past this end of the curb only. NOTE 2: Only the WCY048-060G Models extend past both the end and the side of the curb as illustrated CONVERTING HORIZONTAL TO DOWNFLOW HORIZONTAL SUPPLY...
  • Page 4: Dimensional Data

    CORNER WEIGHT(LBS) UNIT MODEL WEIGHT WCY024G WCY030G WCY036G WCY042G WCY048G WCY060G Page 4 DIMENSIONAL DATA WCY024-060G OUTLINE - BACK 56-1/2 29-3/16 18-9/16 11-1/16 6-9/16 6-13/16 29-1/16 18-9/16 11-1/16 6-9/16 11-1/8 65-1/8 33-1/8 21-1/16 15-1/16 4-15/16 9-1/8 21-15/16 25-3/8 17-1/2 24-3/8 19-1/4 27-1/2 17-1/2 19-1/4 27-1/2...
  • Page 5 WCY024-060G OUTLINE - FRONT RECOMMENDED SERVICE CLEARANCE BACK * 6.0" LEFT SIDE 30.0" RIGHT SIDE 24.0" FRONT SIDE 30.0" * 18" WITH FRESH AIR ACCESSORY * 30" WITH ECONOMIZER DIMENSIONAL DATA MODEL WCY024G 56-1/2 29-3/16 12-15/16 WCY030G WCO36G 29-3/16 WCY042G WCY048G 65-1/8 33-3/8...
  • Page 6 REQUIRED CLEARANCE FOR UNIT INSTALLATION AND ROOF PENETRATION HOLE SIZE REQUIRED SERVICE CLEARANCE LINES SIDE RAIL WOOD NAILER SERVICE CLEARANCE & PENETRATION DIMENSIONS MODEL NO. WCY024-030G 30" 30" *12" 24" WCY036-042G 30" 30" *12" 30" WCY048-060G 42" 30" *12" 36" * 18"...
  • Page 7: Unit Support

    3. For “Roof Top Application,” unit must be elevated above roof with a mounting Curb or Frame. 4. Exhaust vents or other sources of contaminated air should not be near unit air inlet if outside air is to be introduced as a make-up air or the economizer ventilation feature is to be used.
  • Page 8 OUTDOOR COIL END OF UNIT “B” DRIP LIP BAYLIFT002A LIFTING LUGS DIMPLE GASKET SEAL NOTE: The inner perimeter of the Drip Lip on all units should be flush with the outer perimeter of the curb on the two sides shown here. See Figure 2 for the location of the unit overhang on the WCY036-060G Models with BAYCURB030A.
  • Page 9 ROOFTOP -- UNITS For roof top applications using a field fabricated frame and ducts, use the following procedure: 1. The frame must be located and secured by bolting or welding to the roof. Flashing is required. 2. The hole in the roof must be prepared in advance of installing the unit.
  • Page 10 GROUND LEVEL -- HORIZONTAL UNITS For ground level installations, the unit should be positioned on a pad the size of the unit or larger. The unit must be level on the pad. The pad must not come in contact with the structure (See Figure 11.) Be sure the outdoor portion of the supply and return air ducts are as short as possible.
  • Page 11: Condensate Drain Piping

    UNIT EXTERIOR WEATHERPROOF THIS SEAM UNIT DUCT FLANGE FIELD DUCT UNIT EXTERIOR UNIT DUCT FLANGE WEATHERPROOF THIS SEAM FIELD DUCT UNIT EXTERIOR WEATHERPROOF THIS SEAM UNIT DUCT FLANGE FIELD DUCT HORIZONTAL CONDENSATE DRAIN PIPING A 3/4-inch female NPT condensate drain connection is pro- vided on the evaporator access panel end of the unit.
  • Page 12: Filter Installation

    AIR FILTERS Filters are to be used with the WCY024-060G heating/cooling units. The basic unit does not have filters in it. However, a filter frame accessory is offered that will allow filters to be installed within the unit. Otherwise a filter rack must be installed by the installer in the duct work.
  • Page 13 After all electrical wiring is complete, set the thermostat system switch in the OFF position so that the compressor will not run and then apply power by closing the system main disconnect switch. This will activate the compressor sump heat. Do not change the Thermostat System Switch until power has been applied long enough to evaporate any liquid R-22 in the compressor.
  • Page 14 PRE-START QUICK CHECKLIST ● Is the unit properly located and level with the proper clearance? See Figure 5. ● Is the duct work correctly sized, run, taped, insulated, and weatherproofed with proper unit arrangement. See Ductwork Installation section. ● Is the condensate line properly sized, run, trapped, and pitched? ●...
  • Page 15: Sequence Of Operation

    GENERAL Operation of the unit heating and cooling cycles is automatic for HEAT and COOL functions. (The optional automatic changeover thermostat, when in the AUTO position, automatically changes to heat or cool with sufficient room temperature change.) The fan switch can be placed in either the ON position, causing continuous evaporator (indoor) fan operation, or the AUTO position causing fan operation to coincide with heating or cooling run cycles.
  • Page 16: Demand Defrost System

    DEMAND DEFROST SYSTEM DEFROST CONTROL The demand defrost control measures heat pump outdoor ambient temperature with a sensor located outside the outdoor coil. A second sensor located on the outdoor coil is used to measure the coil temperature. The difference between the ambient and the colder coil temperature is the difference or delta-T measurement.
  • Page 17: Demand Defrost Control Checkout

    DEMAND DEFROST CONTROL CHECKOUT SYMPTOMS 1. LED off. 1. 24V R-B & Y-B at board, with unit running? 2.Short FRC_DFT pin to TEST_COMMON pin. Is defrost cycle initiated? 2. LED flashing very rapidly (greater than 4 times/sec) or appears to be on TEST_COMMON pin shorted to TST pin? continuously.
  • Page 18: Maintenance

    ROUTINE MAINTENANCE BY OWNER You can do some of the periodic maintenance functions for your WCY-G unit yourself; this includes replacing the dispos- able or cleaning the permanent air filters, cleaning the unit cabinet, clearing the condenser coil, and conducting a general unit inspection on a regular basis.
  • Page 19 LIMITED WARRANTY HIGH EFFICIENCY HEAT PUMP WCZ, WCY AND WCX Models Less Than 20 Tons for Residential Use* (Parts Only) This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the Heat Pump is originally affixed, and applies to products purchased and retained for use within the U.S.A.
  • Page 20 * This warranty is for commercial usage of said equipment and not applicable when the equipment is used for a residential application. Commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes. The Trane Company Unitary Products Group 6200 Troup Highway...