Download Print this page

Rear View - Ice-O-Matic EMF 800 Specifications

Emf 800 series flake ice maker

Advertisement

Dimensions and Air Flow
16"
23.5"
Air in -
(406 mm)
(597 mm)
Front of
of ICE Maker
32"
Air Out -
(813 mm)
Both Sides
of ICE Maker
(2083 mm)
31"
(787 mm)
30"
(762 mm)
ICE PRODUCTION CHART POUNDS (KILOGRAMS) PER 24 HOURS
EMF 800
Conds.
Air Temp.
Water Temp. °F (°C)
Unit
°F (°C)
80°(27°)
70°(21°)
90° (32°)
588 (267) 632 (287) 691 (314)
Air
80° (27°)
622 (283)
669 (304)
Cooled
70° (21°)
659 (300)
709 (322) 780 (355)
90° (32°)
703 (320) 756 (344) 794 (361)
Water
80° (27°)
696 (316)
748 (340)
Cooled
70° (21°)
720 (327)
774 (352) 852 (387)
All specifications and performance data are
subject to normal manufacturing variances.
ICE Production
per 24 hrs. at
Model
Cond.
70° Air/50° Water
No.
Unit
lbs. (Kgs.)
EMF800AS
Air
780 (355)
EMF800WS
Water
852 (387)
EMF705AS
Air
821 (373)
See Bin specification sheet for information on ICE storage bins
Please note: air-cooled units require 6" (152 mm) clearance for air intake and exhaust.
We reserve the right to make changes in design and construction at any time
without obligation.
2003© ICE-O-Matic
Rev Code: 2005A-07/03-SS
4.50" (114mm)
4.00"
(102mm)
TOP VIEW
82"
EMF 705
Air Temp.
Water Temp. °F (°C)
50°(10°)
°F (°C)
80°(27°)
90° (32°)
568 (258)
736 (334)
80° (27°)
613 (278)
70° (21°)
662 (301)
823 (374)
ORDERING AND SPECIFICATION INFORMATION
Water Used-Gals. (Lits.)
ICE Production
per 100 lbs. of ICE
per 24 hrs. at
90° Air/70° Water
90° Air/70° Water
ICE Prod.
Cond.
lbs. (Kgs.)
Use
Use
632 (287)
12.0 (45)
n/a
756 (344)
12.0 (45)
146.6 (555)
641 (291)
12.0 (45)
n/a
ICE Dispense Area
"To Bin" in Bottom
of Machine-5.50"
(140mm) DIA
16.00"
(406mm)
7/8" (22mm) DIA Hole
for Electrical
Connection to
Control Box
ICE Maker Water Out
1/2" (13mm) I.D.
Plastic Tubing
Condenser Water Out
3/8" (10mm) Copper Tubing
Water Cooled Only
Condenser Water In
3/8" (10mm) Copper Tubing
Water Cooled Only
Ambient Temp. Range
Air & Water
70°(21°)
50°(10°)
Water Temp. Range
641 (291)
625 (284)
Water Pressure Ice Maker
Water in
692 (314)
723 (328)
Condenser Inlet Water
748 (339)
821 (373)
(Water cooled only)
Kilowatts
Used per
100 lbs. of ICE
90° Air
Voltage
70° Water
Btuh
Characteristics
4.3
7693
115/60/1
3.2
8261
115/60/1
4.1
5170
220-240/50/1
ICE-O-Matic 11100 E. 45th Avenue, Denver, CO 80239
Tel. 303 371-3737 Fax. 303 371-6296 www.iceomatic.com
ICE Maker Water In
1/4" (6mm) Male Flare
1.88"
(48mm)
29.75"
(756mm)
21.88"
(556mm)
1.38" (35mm)
2.25" (57mm)
3.88" (99mm)
6.38"
(162mm)

REAR VIEW

OPERATING LIMITS
50° - 104°F (10° - 40°C) 60Hz
50° - 110°F (10° - 43°C) 50Hz
40° - 80°F (4.5° - 27°C)
Min. 20 psi (1.4 bar)
Max. 60 psi (6.9 bar)
Min. 20 psi (1.4 bar)
Max. 60 psi (6.9 bar)
Min.
Max.
Shipping
No. of
Circuit
Fuse
Weight
Wires
Amp.
Size
lbs. (Kgs.)
3
19.8
20
205 (93)
3
16.5
20
205 (93)
3
8.6
15
205 (93)
®

Advertisement

loading

This manual is also suitable for:

Emf800asEmf800wsEmf705as