3-3 Parking Lights Constant: In the default setting, the parking lights (if con-
nected) comes on solid during the remote start runtime. In the two- flash setting
the parking lights will flash during the remote start runtime.
3-4 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 SECONDS:
If the unit is programmed for no engine checking or voltage sense, the crank
time must be set to the appropriate duration. The default setting is 0.6 second.
If a different crank time is desired, you can toggle through the higher settings by
using the two-chirp settings.
3-5 ACTIVATION PULSE 1: This allows the system to use 1 or 2 pulses to acti-
vate the remote start sequence. The default setting is 1-pulse.
Note: This setting affects both the White/Blue input wire and the remote con-
trol.
3-6 2nd IGNITION/ACCESSORY OUTPUT: This will allow the PINK/WHITE to
be used as a 2nd ignition or an accessory. The default is 2nd ignition.
3-7 ACCESSORY STATE DURING WAIT-TO-START OFF/ON: This feature will
allow the selection of the accessory output to be ON or OFF during wait-to-start
time period.
3-8 2nd STATUS OUTPUT NORMAL/REAR DEFOGGER LATCHED 10-MIN/
PULSE: This feature will allow selection of status output or a rear defogger mode
that turns on ten seconds after the vehicle has started if the vehicle interior tem-
perature is below 55 degrees F. The defogger mode has two selections, latched
or pulsed. Latched mode will only stay on for 10 minutes.
3-9 ANTI-GRIND ON/OFF: With the anti-grind On (default) the ground-when-
armed output will be active during remote start operation. If accessories such as
a voice module or window module are added to the unit, it may be necessary
to program this feature off.
3-10 DIESEL TIMER—WAIT-TO-START/15, 30, 45 SECONDS:
Default is
the H2/5 Gray/Black "Wait-to-Start" input control wire. This system has an
onboard timer so the "wait-to-start" control wire does not need to be connected.
The timer can be programmed to a 15, 30 or 45 second delay. This feature can
also be programmed using the Bitwriter® with a delay from 1 to 90 seconds.