Python 680XP Installation Manual page 9

Car security
Hide thumbs Also See for 680XP:
Table of Contents

Advertisement

H1/10 BROWN (+) siren output
Connect this to the RED wire of the Revenger® siren. Connect the BLACK wire of the siren to (-)
chassis ground, preferably at the same point you connect the control module's BLACK ground wire.
H1/11 RED (+)12V constant power input
Before connecting this wire, remove the supplied fuse. Connect to the battery positive terminal or
the constant 12V supply to the ignition switch.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 15 fuse
in the harness for this purpose. This fuse protects the module itself.
H1/12 RED/WHITE 200 mA (-) channel 2 output
When the system receives the code controlling channel 2 for longer than 1.5 seconds, the
RED/WHITE will supply an output as long as the transmission continues. This is often used to
operate a trunk/hatch release or other relay/driven function.
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input!
The transistorized output can only supply 200 mA of current. Connecting directly to a
solenoid, motor, or other high-current device will cause it to fail.
©
2004
Directed Electronics, Inc.
9