10 electrolux e:line gas cooktops LP Gas Conversion
LP Conversion – Important
This appliance is fitted with Natural Gas
burner injectors.
Please follow the procedure below if a conversion to suit
PROPANE or UNIVERSAL LP is required.
The conversion kit contains 5 injectors (square cooktops) or
8 injectors (rectangular cooktops) and 1 LPG sticker.
1. Remove the hotplate burners to access the hotplate
injectors. Replace the factory fitted NG injectors with the
appropriate injectors, as supplied (see Table 3).
2. Unscrew the turret cover nut from the regulator turret.
The turret cover, spacer shim washer and nylon fuel
selector will disengage from the turret as an assembly.
3. Unclip the nylon fuel selector from the turret nut
assembly by rotating the fuel selector 1/4 turn, and
pulling it free from the assembly.
4. Turn over the fuel selector, re-insert and clip back into
position. For LPG operation the closed end of the fuel
selector should be visible when the fuel selector is
clipped into the turret nut.
Table 3
Burner type
Injector size (mm)
Small burner
Medium burner
Large burner
Wok burner
Natural Gas
(Nominal test point pressure: 1.00kPa)
Gas consumption
1.00
1.35
1.60
1.75
5. Refit the turret cover nut assembly to the regulator turret
ensuring that it is fully screwed down. The regulator is
now set for connection to LP.
6. Turn on the gas supply and at each new connection
check for leaks using soapy water: each hotplate valve
should be turned on, one at a time, and the injector
hole blanked off for several seconds.
7. The operation of the regulator can be confirmed by
connecting a manometer to the pressure test point
located on the side of the regulator body adjacent to
the outlet. With the appliance operating check the outlet
pressure
• when all burners of the appliance are operating
at maximum,
• when the smallest burner of the appliance is operating
at minimum.
(Nominal test point pressure: 2.60kPa)
Injector size
(MJ/h)
(mm)
5.1
9.0
12.1
14.4
Propane / Universal LPG
Gas consumption
(MJ/h)
0.55
4.2
0.70
6.5
0.90
10.7
1.00
14.0