Vanguard Vi33NRB Owner's Operation And Installation Manual page 20

Unvented (vent-free) gas fireplace insert
Table of Contents

Advertisement

7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8 starting on page 19.
9. Slightly push in and turn control knob coun-
terclockwise
10. Wait one minute and switch selector switch
to the ON position to light burners.
11. Set flame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
20
OpERATiON
Continued
to the ON position.
to the
www.desatech.com
Pilot
Ignitor
Burner
Electrode
Natural Gas
Figure 32 - Pilot
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote:
Set remote selector switch in the OFF
position to keep from draining battery.
3. Close equipment shutoff valve (see Figure
17, page 15).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting
Instructions, page 19.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11 under Lighting Instructions,
column 1.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 34). Follow instructions included with
the remote control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 19.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust flame adjustment knob anywhere
between HI and LO. Slide selector switch to
REMOTE position (see Figure 33, page 21).
Pilot Burner
Ignitor
Electrode
Propane/LP Gas
to the
113195-01J

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vi33prb

Table of Contents