Notes For The Installer - Scotsman CU50 Installation And User Manual

Cube ice machine
Hide thumbs Also See for CU50:
Table of Contents

Advertisement

CU50
Installation and User's Manual

Notes for the Installer

Sealing to floor: In some cases the base of the ice
machine must be sealed to the floor to meet local
code. Food grade silastic sealant such as
Scotsman part number 19-0529-01 is
recommended.
Place the machine in the intended location. Turn
the leg levelers in until the bottom of the unit is as
close to the floor as possible. Be sure the unit is
level and all four levelers are in contact with the
floor.
Place a bead of the sealant between the floor and
the outside edge of the cabinet. The bead must fill
the space between the cabinet bottom edges and
the floor.
Installations on a slab: Use a pump model and
pump the water to the point of drainage. Pump
models will pump 1 story (10 feet) high.
Installations over a crawl space or basement:
Either gravity drain or pump model units may be
used, if there is not enough room behind the
machine for a drain/waste receptacle, the drain will
have to be below the floor.
Note: When installed in a corner, the door swing
may be limited due to handle contact with the wall
or cabinet face.
March 2010
Page 7

Advertisement

Table of Contents
loading

Table of Contents