Directed Electronics Viper 5501 Installation Manual page 18

Keyless entry and remote start
Hide thumbs Also See for Viper 5501:
Table of Contents

Advertisement

1.
Aux/Trunk Icon Type: sets the name to be displayed in the Text Field when the Aux/Trunk output is acti-
vated/de-activated
2.
Aux 1 Timed Output: sets the output duration in 1 second intervals up to 90 seconds for Aux 1
3.
Aux 1 Icon Type: sets the name to be displayed in the Text Field when the Aux 1 output is activated/
de-activated
4.
Aux 2 Timed Output: sets the Aux 2 "Timed" output in 1 second intervals up to 90 seconds
5.
Aux 2 Icon Type: sets the name to be displayed in the Text Field when the Aux 2 output is activated/
de-activated
6.
Aux 3 Timed Output: sets the Aux 3 "Timed" output in 1 second intervals up to 90 seconds
7.
Aux 3 Icon Type: sets the name to be displayed in the Text Field when the Aux 3 output is activated/
de-activated
8.
Aux 4 Timed Output: sets the Aux 4 "Timed" output in 1 second intervals up to 90 seconds
9.
Diesel Start Delay Timer: sets the delay before engine crank in 1 second intervals up to 90 seconds for
diesel engine vehicles
10.
Timer Mode Runtime: sets the duration of runtime when the engine is started by the Timer Mode and Smart
Start features
11.
Timer mode Starts: sets the number of times the engine will be started by the Timer Mode and Smart Start
features
12.
Timer mode Intervals: sets the number of hours between engine starts by the Timer Mode and Smart Start
features
13.
Smart Start Low Temperature: sets the low temperature threshold required for Smart Start to start the
engine
14.
Smart Start High Temperature: sets the high temperature threshold required for Smart Start to start the
engine
15.
Smart Start Low battery (Volts): sets the low battery level threshold required for Smart Start to start the
engine
16.
Starter Release Fine Tune: adds or subtracts crank time in Tachometer mode in order to overcome engine
types that short crank or over-crank on the first start attempt
17.
Feature Programming: locks and unlocks the user's ability to enter the feature menus and manually
change the main unit programming using the Control Center
18.
Transmitter Programming: locks and unlocks the user's ability to enter the remote control/Reset menu and
manually change any functions using the Control Center
19.
Remote Start Runtime: sets the duration of runtime when the engine is started by remote command
20.
VirtualTach Fine tune: adds or subtracts crank time in VirtualTach mode in order to overcome engine types
that short crank or over-crank on the first start attempt
18
© 2009 Directed Electronics. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Python 951Clifford 20.7x

Table of Contents