H1/11 RED (+)12V constant power input: Before connecting this wire, remove the supplied fuse. Connect to the battery
positive terminal or the constant 12V supply to the ignition switch as described on Page 5.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 10A fuse in the
harness for this purpose. This fuse protects the module itself.
H1/12 RED/WHITE channel 2, 200mA (-) output: When the system receives the code controlling channel, for longer
than 1.5 seconds, the red/white will supply an output as long as the transmission continues. This is often used to
operate a trunk/hatch release or other relay-driven function.
NOTE: If an instant output is desired, press Button I & II at the same time
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! The transistorized output
can only supply 200 mA of current, connecting directly to a solenoid, motor, or other high-current device will
cause it to fail.
RED/WHITE H1/12
RED/WHITE H1/1
FUNCTION 2 OUTPUT
CHANNEL 2 OUTPUT
(+) 12V CONSTANT FUSED
These plug into the module. The Status LED plugs into the small two-pin socket, while the Valet
should be plugged into the larger blue two-pin connector. The Status LED fits in a 9/32" hole.
Status LED
ON-BOARD STINGER
There is a full-fledged Stinger
indicated above. Since the Stinger
recommend against screwing down the control module.
NOTE: When adjusting the sensor, it must be in the same mounting location that it will be after the install is
completed. Adjusting the sensor and then relocating the module requires readjustment.
© 1995,1997 Directed Electronics, Inc. Vista, CA
PLUG-IN LED AND VALET
DOUBLE GUARD
Less sensitive
shock sensor inside the control unit. Adjustments are made via the rotary control as
shock sensor does not work well when mounted too firmly to metal, we
(+)12V IF (+) SWITCHED
(-) GROUND IF (-) SWITCHED
87A
87
85
86
30
SWITCHED TRUNK RELEASE WIRE
®
/ PROGRAM SWITCH
Valet
SHOCK SENSOR
É
Ê
More sensitive