Soleus Air PH5-13R-32D Operating Instructions Manual page 12

Portable air conditioner with heat pump
Table of Contents

Advertisement

°
°
68
F to 80
F. And Air Conditioner mode when the room temperature is above 80
the room temperature is below 68
Sleep Mode (This mode can only be selected when using the Remote control )
1) To set Sleep mode, make sure the unit is in Air Conditioner mode or Heating mode.
2) Press the SLEEP Button on the remote control. The "
3) When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.
4) When in Air Conditioner mode, the temperature setting will gradually increase to 2
temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.
5) When in Heating mode, the temperature setting will gradually decrease to 2
perature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.
6) When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.
Compressor Indicator
The "
" icon will light up on the control panel display when the compressor turns on. The "
will turn off when the compressor shuts off.
Emergency Condensate Holding Tank
When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency
condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut
off and the "
" will appear on the control panel display. To empty the condensate tank, pull the drain plug
at the bottom back of the unit. You will need a small pan, approximately 1" high to catch the water coming out
of the condensate tank. Connect the supplied drainage hose to the back of the unit to aid in drainage into the
pan. Once the condensate tank is drained, the unit will begin working within a few minutes. The emergency
condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small hose from a hard-
ware store that can fit around the 5/8" drain plug on the back of the unit and drain the unit into a gravity drain
or larger pan for continuous drainage. It is not advised to use continuous drainage when the room temperature
°
is higher than 90
F .
If you do not need the emergency tank emptied immediately simply leave the unit on. The fan in your air con-
ditioner will continue to run to help evaporate the moisture as fast as possible. This will usually take around 60
minutes depending on how much water is in the tank.
°
F .
" icon appears on the control panel display.
12
°
F. Heating Mode when
°
F above the original set
°
F below the original set tem-
" icon

Advertisement

Table of Contents
loading

Table of Contents