the users must be notified the change for the connection to be successful. For
instance, when the Administrator changes the HTTP port of the Network
Camera whose IP address is 192.168.0.100 from 80 to 8080, the users must
type
in
the
web
"http://192.168.0.100".

Streaming

"Control channel port" This can be something other than the default port 5001 in
order to work with the port opened by the firewall.
"Audio channel port" This can be something other than the default port 5002 in
order to work with the port opened by the firewall.
"Video channel port" This can be something other than the default port 5003 in
order to work with the port opened by the firewall.
"Improve audio quality in low bandwidth environment" If the Network Camera
seems to work in a low bandwidth network environment, the user can use this
option to see if audio quality can be improved by sacrificing some real-time
synchronization.
"Mute" This can force the transmission protocol to HTTP and disable audio.
Some invalid settings may cause the system failing to respond. Change the
configuration only if necessary and consult with your network supervisor or
experienced users for correct settings. Once the system has lost contact, refer
to Appendix A for reset and restore procedures.