Metering Device; Charging Subcooling; Specifications - Payne PA10 Series Product Data

10 seer 3-phase air conditioner
Hide thumbs Also See for PA10 Series:
Table of Contents

Advertisement

METERING DEVICE

UNIT SIZE-SERIES
036-A
048-A
060-A
* Piston listed is for any approved coil non-capillary tube combination.
Piston is shipped with outdoor unit and must be installed in an approved indoor coil.
UNIT SIZE
SERIES
Operating Weight (Lb)
Shipping Weight (Lb)
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor—Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°C/75°F Copper) AWG†
Max Wire Length (60°C/75°F) (Ft)‡
Max Branch Circuit Fuse Size**
COMPRESSOR & REFRIGERANT
Compressor—Type
Temperature and Current Protection
Refrigerant—Type and Amount (Lbs)
Refrigerant Tubes (In. OD)
Vapor and Liquid (Up to 50 Ft)
CONDENSER COIL & FAN
Coil Face Area (Sq Ft)
Fan Motor—HP, Type, and RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Cycle Protector
Low-Pressure Switch
High-Pressure Switch
Time-Delay Relay
Winter Start Control
Evaporator Freeze Thermostat
Compressor Crankcase Heater
Liquid Line Solenoid Valve
Filter Drier
MotorMaster® Control
Ball Bearing Fan Motor
Low-Ambient Pressure Switch Kit
Compressor Sound Hood
TXV (Hard Shutoff)
Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool‡‡
Thermostat, Manual Changeover,
5-2-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Backplate for Standard Thermostat
Backplate for Programmable Thermostat
Outdoor Air Temperature Sensor
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article
336-26.
‡ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time-delay fuse or circuit breaker.
‡‡ Furnace model numbers P08UA, P08LA, and PG8HA are not compatible with this thermostat.
N/A—Not applicable in this application.
NOTES: 1. Control circuit is 24v on all units and requires external power source.
2. All motors/compressors contain internal overload protection.
3. Copper wire must be used from service disconnect to unit.
PISTON*
IDENTIFICATION NO.
70
82
93

SPECIFICATIONS

036
A
122
141
208/230-60-3
187-253
10.0
70.0
1.4
13.9
14/14
65/62
20
Reciprocating
R-22 5.00
3/4 and 3/8
9.1
1/4 PSC and 1100
208/230—60—1
2500
KAACH1001AAA
KAALS0101LLS
P502-8083S
KSASH1201COP
KSATX0601HSO
—4—

CHARGING SUBCOOLING

(TXV-TYPE EXPANSION DEVICE*)
UNIT SIZE
036
048
060
048
A
A
154
175
208/230-60-3
208/230-60-3
187-253
187-253
12.8
16.0
91.0
125.0
1.4
1.4
17.4
21.4
14/14
12/12
52/49
66/63
30
30
Scroll
Internal Line Break
R-22 6.25
7/8 and 3/8
12.4
1/4 PSC and 1100
208-230—60—1
2500
KSACY0101AAA
KAALP0101LPS
KSAHI0101HPS
KAATD0101TDR
KAAWS0101AAA
KAAFT0101AAA
KAACH1201AAA
KAALS0101LLS
P502-8163S
32LT660004
HC40GE232
KSALA0201R22
KSASH2001CYL
KSATX0701HSO
TSTATPPBAC01-B
TSTATPPSAC01-B
TSTATXXBBP01
TSTATXXPBP01
TSTATXXSEN01-B
REQUIRED SUBCOOLING
(°F)
15
15
15
060
A
214
236
460-60-3
414-506
8.0
66.5
0.8
10.8
14/14
165/157
15
R-22 8.31
1-1/8 and 3/8
18.5
460—60—1
3400
KAACH1301AAA
32LT660005
HC40GE462
KSATX1001HSO