esp
(Effective System Protection):
maximum system output with
The ESP sizing procedure covers modern residential water-use habits, increased off-peak
demands and the general increase in water use that have occurred over the past twenty-five years.
ESP sizing is designed to reduce pump wear and tear, and reduce energy consumption by keeping
pump starts to a minimum.
Choose the amount of protection you need.
ESP I: Tank selection is based on approximately one minute minimum pump running time.
This is recommended for pumps up to 3/4 H.P.
ESP II: Tank selection is based on approximately two minute minimum pump running time.
This is recommended for 3/4 H.P. or larger pumps.
PUMP DISCHARGE
RATE GPM (Approx.)
minimal pump starts
ESP Sizing Table
20/40
5
WX-202
7
WX-202
10
WX-202XL
12
WX-205
15
WX-250
20
WX-251
25
WX-251
30
WX-255
35
WX-302
40
WX-350
OPERATING PRESSURE - PSIG
ESP I
30/50
40/60
WX-202
WX-202
WX-202XL
WX-202
WX-202XL
WX-205
WX-205
WX-250
WX-250
WX-250
WX-251
WX-251
WX-255
WX-255
WX-302
(2) WX-251
WX-302
WX-350
(2) WX-255
WX-350
WX-350
(2) WX-302
WX-350
(2) WX-255
(2) WX-350
ESP II
20/40
30/50
40/60
WX-205
WX-205
WX-205
WX-250
WX-251
WX-251
WX-251
WX-255
WX-251
WX-255
WX-255
WX-255
WX-302
WX-350
WX-350
WX-350
(2) WX-255
(2) WX-255
(2) WX-302
(2) WX-302
(2) WX-350
(2) WX-350
(2) WX-350
(2) WX-350
(3) WX-302