NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal
injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current
copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER
HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL
INJURY AS WELL AS PROPERTY DAMAGE.
READ
INSTALLATION & OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE
MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR
PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY.
THIS
PRODUCT
MUST
PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE
CODES AND REGULATIONS. IN THE ABSENCE OF SUCH CODES,
FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING
CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.
EXPLOSION OR RUPTURE HAZARD. THE WELL TANK MUST BE
OPERATED SO THAT THE PRESSURE DOES NOT EXCEED THE
MAXIMUM WORKING PRESSURE.
EXPLOSION HAZARD. Failure to follow the
instructions in the product manual can cause a
rupture or explosion; possibly causing serious or fatal injury, leaking or
flooding and/or property damage.
Use only with a potable water system.
operate in a setting with freezing temperatures or
where the temperature can exceed 130°F and do not exceed the
maximum working pressure specified for this Product in the Manual.
Mount vertically only.
Chlorine & Aggressive Water: The water quality
can significantly influence the life of this Product.
You should test for corrosive elements, acidity, total solids and other
relevant contaminants, including chlorine and treat your water appropriately
to insure satisfactory performance and prevent premature failure.
RESIDENTIAL PRE-PRESSURIZED WELL TANKS
INSTALLATION & OPERATION INSTRUCTIONS
CAREFULLY
THE
BE
INSTALLED
BY
A
Models WX-101 through WX-350
PRODUCT
causing serious or fatal injury, leaking or flooding and/or property damage.
To minimize risk, a licensed professional must install and periodically
inspect and service the Product. A drip pan connected to an adequate
LICENSED
drain must be installed if leaking or flooding could cause property damage.
Do not locate in an area where leakage of the tank or connections could
cause property damage to the area adjacent to the appliance or to lower
floors of the structure.
local code requirement or maximum working pressure designated in the
Product Manual, whichever is less. Do not expose Product to freezing
temperatures or temperatures in excess of 130°F. Do not adjust the pre-
charge or re-pressurize this Product except for any adjustments required
at the time of initial installation, especially if Product is corroded,
damaged or has diminished integrity. Adjustments to pre-charge must
be done at ambient temperature only.
Do not
Product or follow these instructions may result in excessive strain on the
system, lead to Product failure, serious or fatal personal injury, leakage
and/or property damage.
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov.
WELL-X-TROL
This Product, like most Products under pressure,
may over time corrode, weaken and burst or explode,
EXPLOSION OR RUPTURE HAZARD A relief valve
must be installed to prevent pressure in excess of
Failure to properly size the
This product can expose you to chemicals including
lead, which is known to the State of California to
®

Advertisement

loading

Summary of Contents for Amtrol WELL-X-TROL WX-101

  • Page 1 Current copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing. THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS.
  • Page 2 PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS. DANGER! EXPLOSION HAZARD. WHEN THE CONSULT YOUR LOCAL PLUMBING OFFICIAL REGARDING ANY WELL TANK HAS BEEN IN SERVICE AND A STEPS YOU MAY WISH TO TAKE TO SAFELY DISINFECT YOUR CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY HOME’S PLUMBING SYSTEM.
  • Page 3: Pre-Installation

    Installation of In-Line Turbulator Installation ™ System Connection The In-Line Turbulator water circulation device is designed to circulate the water stored in your diaphragm well tank. In-line Models: 1. Inspect the In-Line Turbulator for any damage that may WX-101 through WX-103: ¾" NPTM have occurred during shipping.
  • Page 4: Suggested Piping Diagrams

    Suggested Piping Diagrams In-line Models: Horizontal Models: WELL-X-TROL RELIEF VALVE WELL-X-TROL PUMP Underground Models: PRESSURE TANK LOCATION STICKER SUPPLIED WITH EACH UNIT RELIEF VALVE WELL POSSIBLE PRESSURE SWITCH LOCATION BUILDING FOUNDATION PRESSURE TANK LOCATION, FOR EXAMPLE FROST LINE TO HOUSE WELL-X-TROL "UG"...
  • Page 5 Suggested Piping Diagrams (cont.) Vertical Models: WELL-X-TROL WELL-X-TROL UNIVERSAL PUMP STAND 398096 WELL-X-TROL...
  • Page 6: Maintenance

    Well-X-Trol, yearly and more frequently as the system ages. Warranty WX Models: Seven (7) Year Limited Warranty Visit www.amtrol.com for complete warranty details and to register the serial number of your well tank. Pressure Adjustment: • Clockwise to increase cut-out pressure.

This manual is also suitable for: