Carrier 50ZH Product Data page 11

Single-package units 2 to 5 nominal tons
Table of Contents

Advertisement

50ZH048 (4 TONS)
Temp (F)
Air Ent
Outdoor
Coil
(edb)
72
67
TC
57.4
52.5
85
SHC
27.1
34.7
kW
3.63
3.60
TC
55.1
50.0
95
SHC
26.4
33.7
kW
4.06
4.02
TC
52.8
47.4
105
SHC
25.6
32.8
kW
4.49
4.44
TC
42.0
38.0
115
SHC
37.7
31.1
kW
4.61
5.79
50ZH060 (5 TONS)
Temp (F)
Air Ent
Outdoor
Coil
(edb)
72
67
TC
65.7
59.9
85
SHC
33.7
43.4
kW
5.55
5.45
TC
63.1
55.0
95
SHC
32.9
41.9
kW
5.94
5.85
TC
60.2
53.6
105
SHC
31.9
40.8
kW
6.37
6.28
TC
57.3
51.2
115
SHC
30.9
40.1
kW
6.80
6.71
LEGEND
BF
— Bypass Factor
Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW
— Total Unit Power Input
Ldb — Leaving Dry-Bulb
Lwb — Leaving Wet-Bulb
SHC — Sensible Heat Capacity (1000 Btuh) Net
TC
— Total Capacity (1000 Btuh) Net
*At 75 F entering dry bulb (Tennessee Valley Authority [TVA] rating
conditions); all others at 80 F entering dry bulb.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
t ldb = t edb –
1.10 x cfm
COOLING CAPACITIES (cont)
Indoor Entering Air — CFM/BF
1400/0.08
Indoor Entering Air — Ewb (F)
63*
62
72
43.8
41.2
57.7
31.7
40.1
27.8
4.39
4.26
3.72
41.3
39.3
55.5
30.7
38.6
27.2
4.82
4.75
4.15
38.6
37.4
53.4
29.6
37.0
26.7
5.25
5.24
4.59
36.1
48.4
42.6
28.1
46.4
40.5
5.73
5.81
4.71
Indoor Entering Air — CFM/BF
1800/0.04
Indoor Entering Air — Ewb (F)
63*
62
72
55.5
54.4
66.4
50.8
52.5
35.2
5.35
5.33
5.67
52.8
51.8
64.1
49.6
51.1
34.5
5.74
5.72
6.08
49.9
49.3
61.0
48.3
49.3
33.6
6.18
6.16
6.50
47.1
46.7
58.0
47.0
46.7
32.7
6.61
6.60
6.92
1600/0.08
67
63*
62
72
53.0
44.4
42.6
58.2
36.9
33.7
42.4
29.0
3.70
4.50
4.38
3.84
46.0
41.9
40.6
56.0
36.0
32.8
40.5
28.3
4.12
4.93
4.87
4.26
48.1
39.0
38.6
53.8
35.0
31.6
38.5
27.7
4.54
5.36
5.36
4.68
38.3
36.4
49.4
43.1
33.5
30.5
49.4
42.9
5.89
5.84
5.94
4.81
2000/0.05
67
63*
62
72
60.8
56.5
55.7
67.3
46.5
54.4
55.7
36.8
5.58
5.48
5.47
5.82
58.1
53.7
53.5
64.7
45.4
53.1
53.4
36.3
5.98
5.87
5.88
6.21
54.9
51.2
51.1
61.7
44.3
51.1
51.1
35.3
6.40
6.32
6.33
6.64
51.8
48.7
48.7
58.6
43.1
48.7
48.7
34.3
6.83
6.77
6.78
7.07
t lwb = Wet-bulb temperature corresponding to enthalpy of air
leaving indoor coil (h lwb )
h lwb = h ewb –
Where: h ewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evapo-
rator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 – BF) x (edb – 80).
1800/0.09
67
63*
62
53.7
45.0
44.5
38.6
35.7
44.5
3.78
4.59
4.51
51.2
42.3
42.2
37.8
34.7
42.2
4.21
5.03
4.99
48.7
39.5
39.8
37.0
33.5
39.8
4.63
5.47
5.48
38.7
36.7
50.9
35.7
32.5
50.9
6.00
5.94
6.08
2250/0.06
67
63*
62
61.7
57.4
57.4
49.4
57.3
57.4
5.71
5.61
5.62
58.8
55.3
55.0
48.3
55.2
55.0
6.09
6.02
6.03
55.7
52.7
52.6
47.2
52.7
52.6
6.52
6.47
6.48
52.6
50.1
50.2
46.1
50.1
50.1
6.95
6.92
6.93
total capacity (Btuh)
4.5 x cfm
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50zh02450zh03050zh03650zh04250zh04850zh060

Table of Contents