Carrier 50ZH Product Data page 10

Single-package units 2 to 5 nominal tons
Table of Contents

Advertisement

Performance data (cont)
50ZH036 (3 TONS)
Temp (F)
Air Ent
1050/0.09
Outdoor
Coil
(edb)
72
67
TC
39.9
35.8
85
SHC
19.1
24.2
kW
3.49
3.37
TC
38.5
34.5
95
SHC
18.7
23.7
kW
3.80
3.67
TC
36.9
33.0
105
SHC
18.2
23.2
kW
4.15
4.01
TC
35.2
31.4
115
SHC
17.6
22.6
kW
4.51
4.36
50ZH042 (3
1
TONS)
2
Temp (F)
Air Ent
1225/0.11
Outdoor
Coil
(edb)
72
67
TC
45.9
41.1
85
SHC
22.1
28.0
kW
4.28
4.15
TC
43.9
39.2
95
SHC
21.5
27.3
kW
4.65
4.51
TC
41.8
37.2
105
SHC
20.8
26.6
kW
5.00
4.90
TC
39.7
35.2
115
SHC
20.1
25.8
kW
5.44
5.32
LEGEND
BF
— Bypass Factor
Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW
— Total Unit Power Input
Ldb — Leaving Dry-Bulb
Lwb — Leaving Wet-Bulb
SHC — Sensible Heat Capacity (1000 Btuh) Net
TC
— Total Capacity (1000 Btuh) Net
*At 75 F entering dry bulb (Tennessee Valley Authority [TVA] rating
conditions); all others at 80 F entering dry bulb.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
t ldb = t edb –
1.10 x cfm
10
COOLING CAPACITIES (cont)
Indoor Entering Air — CFM/BF
1200/0.11
Indoor Entering Air — Ewb (F)
63*
62
72
67
33.1
32.3
40.5
36.4
23.4
29.0
19.9
25.7
3.29
3.27
3.57
3.45
31.8
31.0
39.1
34.2
22.9
28.4
19.5
25.2
3.58
3.56
3.88
3.75
30.4
29.6
37.5
33.5
22.4
27.8
19.0
24.7
3.91
3.89
4.23
4.08
28.9
28.2
35.7
31.9
21.8
27.1
18.5
24.1
4.26
4.24
4.60
4.44
Indoor Entering Air — CFM/BF
1400/0.13
Indoor Entering Air — Ewb (F)
63*
62
72
67
38.0
37.0
46.6
41.8
27.1
33.5
23.2
29.8
4.06
4.04
4.37
4.24
36.2
35.2
44.6
40.0
26.4
32.7
22.5
29.1
4.42
4.39
4.74
4.60
34.3
33.4
42.5
37.8
25.6
31.8
21.8
28.3
4.80
4.78
5.09
4.99
32.4
31.5
40.2
35.7
24.8
30.8
21.1
27.5
5.21
5.19
5.53
5.41
1350/0.12
63*
62
72
67
33.7
32.9
40.9
36.8
24.8
30.8
20.7
27.0
3.36
3.35
3.64
3.52
32.3
31.6
39.4
35.4
24.3
30.3
20.4
26.6
3.66
3.64
3.95
3.82
30.9
30.1
37.9
33.8
23.8
29.6
19.9
26.1
3.99
3.97
4.30
4.16
29.3
28.7
36.1
32.1
23.2
28.7
19.3
25.5
4.34
4.33
4.68
4.52
1575/0.14
63*
62
72
67
38.6
37.6
47.2
42.3
28.7
35.6
24.2
31.5
4.15
4.13
4.45
4.32
36.8
35.8
45.2
40.3
28.0
34.7
23.5
30.8
4.50
4.48
4.82
4.68
34.8
34.0
42.9
38.2
27.2
33.7
22.8
30.0
4.89
4.87
5.17
5.07
32.8
32.3
40.7
36.0
26.4
32.3
22.1
29.2
5.30
5.29
5.61
5.50
t lwb = Wet-bulb temperature corresponding to enthalpy of air
leaving indoor coil (h lwb )
total capacity (Btuh)
h lwb = h ewb –
4.5 x cfm
Where: h ewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evapo-
rator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 – BF) x (edb – 80).
63*
62
34.0
33.3
26.0
32.4
3.43
3.42
32.7
32.0
25.6
31.8
3.73
3.72
31.2
30.8
25.1
30.8
4.06
4.05
29.6
29.6
24.5
29.5
4.14
4.42
63*
62
39.1
38.2
30.3
37.5
4.23
4.21
37.2
36.4
29.6
36.4
4.58
4.56
35.2
34.9
28.8
34.9
4.97
4.97
33.1
33.3
27.9
33.3
5.40
5.40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50zh02450zh03050zh03650zh04250zh04850zh060