Performance Data; Electrical Data - Carrier 58CMA Product Data

Multipoise oil furnace input capacities: 70,000 thru 154,000 btuh series 130
Table of Contents

Advertisement

PERFORMANCE DATA

UNIT SIZE
DIRECT ---DRIVE MOTOR Hp (PSC)
MOTOR FULL LOAD AMPS
RPM (Nominal) --- SPEEDS
BLOWER WHEEL DIAMETER X WIDTH (In.)
FILTER SIZE (In.) --- (Disposable, Field Supplied)
AIR DELIVERY - -CFM (WITH FILTER)
BLOWER
UNIT SIZE
MOTOR HP
105---12
1/3 PSC
120---20
3/4 PSC

ELECTRICAL DATA

UNIT SIZE
UNIT VOLTS---HERTZ --- PHASE
OPERATING VOLTAGE RANGE (Min---Max)*
MAXIMUM UNIT AMPS
MINIMUM WIRE SIZE (AWG)
MAXIMUM WIRE LENGTH (Ft){
MAXIMUM FUSE SIZE OR CKT BKR (Amps)}
TRANSFORMER (24v)
EXTERNAL CONTROL POWER AVAILABLE
AIR CONDITIONING RELAY
* Permissible limits of the voltage range at which the unit will operate satisfactorily.
{ Length is a measured one way along wire path between unit and service panel for maximum 2% voltage drop.
} Time ---delay fuse type is recommended.
SPEED
0.2
0.3
High
1425
1350
Med --- High
1130
1045
Med --- Low
840
810
Low
725
730
High
2080
2040
Med --- High
1890
1860
Med --- Low
1555
1475
Low
1220
1165
Heating
Cooling
105---12
1/3
6.2
1075--- 4
10 x 10
16 x 24 or 25 x 1
EXTERNAL STATIC PRESSURE (In. wc)
0.4
0.5
0.6
1305
1250
1170
1000
950
885
770
740
685
740
745
730
1965
1865
1700
1770
1675
1550
1395
1320
1210
1080
1000
925
105---12
115 --- 60 --- 1
104 --- 132
12.2
14
26
15
40va
40va
30va
Standard
5
120---20
3/4
9.5
1075--- 4
12 x 10
20 x 30 x 1
0.7
0.8
0.9
1030
925
805
820
745
670
635
580
500
715
690
665
1575
1475
1335
1450
1330
1215
1135
1050
940
855
780
655
120---20
115 --- 60 --- 1
104 --- 132
15.7
12
26
20
40va
40va
30va
Standard