Combination ratings*

UNIT
INDOOR
SIZE-SERIES
UNIT
FB4BNF018
FB4BNF024
018-3A
FA4CN(F,C)018
FA4CN(F,C)024
FB4BNF024
FB4BNF030
024-3A
FA4CN(F,C)024
FA4CN(F,C)030
FB4BNF030
FB4BNF036
030-3A
FA4CN(F,C)030
FA4CN(F,C)036
FB4BNF036
FB4BN(F,B)042
036-3A
FA4CN(F,C)036
FA4CN(F,C)042
FB4BN(F,B)042
FB4BN(F,B)048
042-3A
FA4CN(F,C)042
FA4CN(F,C)048
FB4BN(F,B)048
FB4BN(F,B)060
048-3A
FB4BNB070
FA4CN(F,C)048
FA4CN(F,C)060
FB4BN(F,B)060
060-3A
FB4BNB070
FA4CN(F,C)060
* Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor
unit.
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
3. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 125°F (51.7°C).
COOLING CAPACITY @ 95°F (35°C)
NOMINAL AIRFLOW
RATED CAPACITY
CFM
L/S
BTUH
600
280
17,000
600
280
17,600
600
280
17,600
600
280
17,800
800
380
23,200
800
380
23,500
800
380
23,500
800
380
23,800
1000
467
28,600
1000
467
28,800
1000
467
29,000
1000
467
29,200
1200
550
33,500
1200
550
33,800
1200
550
33,800
1200
550
34,400
1400
653
41,000
1400
653
41,500
1400
653
41,500
1400
653
42,400
1600
750
47,500
1600
750
48,500
1600
750
49,000
1600
750
48,000
1600
750
49,000
2000
919
57,500
2000
919
58,000
2000
919
58,000
POWER
RATED
kW
kW
EER
4.98
1.81
9.40
5.16
1.83
9.60
5.16
1.83
9.60
5.22
1.84
9.70
6.80
2.39
9.70
6.89
2.40
9.80
6.89
2.40
9.80
6.97
2.43
9.80
8.38
3.04
9.40
8.44
3.06
9.40
8.50
3.05
9.50
8.56
3.07
9.50
9.82
3.72
9.00
9.90
3.63
9.30
9.90
3.63
9.30
10.08
3.62
9.50
12.01
4.56
9.00
12.16
4.51
9.20
12.16
4.51
9.20
12.42
4.56
9.30
13.92
5.05
9.40
14.21
5.16
9.40
14.36
5.16
9.50
14.06
5.05
9.50
14.36
5.16
9.50
16.85
6.39
9.00
16.99
6.24
9.30
16.99
6.24
9.30
COOLING CAPACITY @ 115°F (46°C)
RATED CAPACITY
POWER
BTUH
kW
kW
14,000
4.10
2.06
15,000
4.39
2.14
15,500
4.54
2.21
15,500
4.54
2.21
18,700
5.48
2.75
19,000
5.57
2.71
19,500
5.71
2.79
19,500
5.71
2.79
23,200
6.80
3.41
23,500
6.89
3.36
23,800
6.97
3.40
24,000
7.03
3.43
27,800
8.15
4.09
28,200
8.26
4.03
28,500
8.35
4.07
29,200
8.56
4.17
34,400
10.08
5.06
35,000
10.25
5.00
35,800
10.49
5.11
36,600
10.72
5.23
41,000
12.01
6.03
42,000
12.31
6.00
42,800
12.54
5.94
42,800
12.54
6.11
43,800
12.83
6.08
49,500
14.50
7.62
50,500
14.80
7.43
50,500
14.80
7.43
9