Carrier 38CKC Product Data

Carrier 38CKC Product Data

60 hz air conditioner sizes 018 thru 060

Advertisement

Copyright 1999 Carrier Corporation
Product
Data
60 Hz Air Conditioner
Sizes 018 thru 060
Model 38CKC Energy-Efficient Air
Conditioner incorporates innovative
technology to provide reliable summer
cooling performance. Built into these
units are the features most desired by
homeowners today, including SEER
ratings of up to 11.5 when used
with components designated by
manufacturer. All models are listed
with UL, c-UL, ARI, CEC, and
CSA-EEV.

AVAILABLE OPTIONS

Electrical Range — All units are
offered in 208–230v single phase.
Three-phase units are available from
030 through 060 sizes in 208/230v and
from 036 through 060 sizes in 460v.
Wide Range of Sizes — The 38CKC
is available in 7 nominal sizes from
018 through 060 to meet the needs of
residential and light commercial
applications.
Weather Armor II Cabinet — The
steel is protected with a galvanized
coating and treated with a layer of zinc
phosphate. A modified polyester
powder coating is then applied and
baked on, providing each unit with a
hard, smooth finish that will last for
many years.
All screws on cabinet exterior are
coated for a long-lasting, rust-resistant,
quality appearance.
Totally Enclosed Fan Motor —
Provides greater reliability under
adverse conditions and dependable
performance for many years. The
permanent-split-capacitor-type motor
was designed for optimum efficiency.
The motor was then qualified under
extreme conditions to help ensure a
long, reliable life.
38CKC
Form 38CKC-4PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38CKC

  • Page 1 Three-phase units are available from 030 through 060 sizes in 208/230v and from 036 through 060 sizes in 460v. Wide Range of Sizes — The 38CKC is available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications.
  • Page 2: Model Number Nomenclature

    fin coil is valves are brass, front seating type. The compressor is protected with internal designed for optimum heat transfer. 38CKC has sweat field connections. temperature- and current-sensitive Vertical air discharge carries sound and Valves are externally located so overloads.
  • Page 3: Physical Data

    Physical data 036-30, 53/31, 51, 042-30, 52/31, 048-30, 52, 060-30, 52, UNIT SIZE 018-30/33 024-30/33 030-30, 50/33 61/34 51, 61 62/31, 51, 61 62/31, 51, 61 OPERATING WT (Lb) 192/198 113/115 115/117 124/122 129/138/138 138/142 231/218 COMPRESSOR Copeland Copeland Copeland Millennium Scroll/ Millennium Millennium...
  • Page 4 Accessories PART NO. DESCRIPTION KAATD0101TDR Time-Delay Relay — All Sizes P251-0083 (RCD) Low-Ambient Controller — Sizes 030–060 KSALA0201R22 Low Ambient Kit — Sizes 018–036, 042 (30, 31, 50, 52, 61), 048-060 32LT660004 (RCD)* MotorMaster® Control — Sizes 030–060 230v 32LT660005 (RCD)* MotorMaster®...
  • Page 5 THERMOSTAT PKG. DESCRIPTION TSTATCCNAC01-B Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATCCPAC01-B Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATCCBAC01-B Builder’s Thermostat, Manual Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATCCSEN01-B Outdoor Air Temperature Sensor TSTATXXNBP01 Backplate for Non-Programmable Thermostat TSTATXXPBP01...
  • Page 6 Accessory description and usage continued Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where Winter Start Control has been added. Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow. SUGGESTED USE: All split-system air conditioners.
  • Page 7: Electrical Data

    Electrical data 60°C 75°C 60°C 75°C OPER VOLTS* COMPRESSOR UNIT WIRE WIRE LENGTH LENGTH MAX FUSE** OR SIZE V/PH SIZE† SIZE† (Ft)‡ (Ft)‡ CKT BKR AMPS 018-30 49.0 12.8 018-33 48.0 12.1 024-30 56.0 10.7 14.4 024-33 60.0 11.6 15.5 030-30 75.0 14.2...
  • Page 8 Dimensions — 38CKC...
  • Page 9 Combination ratings SEER FACTORY- SUPPLIED Carrier Gas INDOOR TOT. CAP. ENHANCE- Standard Furnace or Accessory UNIT MODEL BTUH MENT Rating TDR† TXV‡ EERA SIZE-SERIES CC5A/CD5AA018* 17,200 NONE — 10.00 10.00 9.20 CC5A/CD5AA024 17,600 NONE 10.00 10.50 10.50 9.45 CC5A/CD5AW024 17,600 NONE 10.00...
  • Page 10: Combination Ratings Continued

    Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas INDOOR TOT. CAP. ENHANCE- Standard Furnace or Accessory UNIT MODEL BTUH MENT Rating TDR† TXV‡ EERA SIZE-SERIES CD5A/CD5AA030* 28,000 NONE 10.00 10.10 10.10 9.10 CC5A/CD5AA036 29,000 NONE 10.00 10.10 10.10 9.30 CC5A/CD5AW030...
  • Page 11 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas INDOOR TOT. CAP. ENHANCE- Standard Furnace or Accessory UNIT MODEL BTUH MENT Rating TDR† TXV‡ EERA SIZE-SERIES CE3AA042 33,600 NONE 10.00 10.20 10.20 9.25 CF5AA036 33,600 NONE 10.00 10.20 10.20 9.15 CK3BA036...
  • Page 12 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas INDOOR TOT. CAP. ENHANCE- Standard Furnace or Accessory UNIT MODEL BTUH MENT Rating TDR† TXV‡ EERA SIZE-SERIES COILS + 58U(H,X)V100-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 33,400 10.80 — 10.80 10.05 CD5AW036 33,400 10.50 —...
  • Page 13 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas INDOOR TOT. CAP. ENHANCE- Standard Furnace or Accessory UNIT MODEL BTUH MENT Rating TDR† TXV‡ EERA SIZE-SERIES COILS + 58U(H,X)V120-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 40,000 10.50 — 10.50 9.50 CC5A/CD5AW048 40,000 10.70 —...
  • Page 14 † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in perfor- mance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
  • Page 15 Detailed cooling capacities* CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Kw** Kw** Kw** 38CKC018-30, 33 Outdoor Section With CC5A/CD5AA018 Indoor Section 21.0 10.0 1.77...
  • Page 16 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Kw** Kw** Kw** 38CKC024-30, 33 Outdoor Section With CC5A/CD5AA024 Indoor Section 27.2 13.2...
  • Page 17 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Kw** Kw** Kw** 38CKC030-30, 33, 50 Outdoor Section With CC5A/CD5AA030 Indoor Section 34.0 16.4...
  • Page 18 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 38CKC036-30, 31, 34, 51, 53, 61 Outdoor Section With CC5A/CD5AA036 Indoor Section 41.3 20.5...
  • Page 19 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 38CKC036-30, 31, 34, 51, 53, 61 Outdoor Section With CC5A/CD5AA036 Indoor Section continued 41.3 20.5...
  • Page 20 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Kw** Kw** Kw** 38CKC042-30, 31, 51, 52, 61 Outdoor Section With CC5A/CD5AA042 Indoor Section 48.6 23.6...
  • Page 21 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 38CKC042-30, 31, 51, 52, 61 Outdoor Section With CC5A/CD5AA042 Indoor Section continued 48.6 23.6...
  • Page 22 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 38CKC048-30, 31, 51, 52, 61, 62 Outdoor Section With CD5AA048 Indoor Section 54.3 26.2...
  • Page 23 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Kw** Kw** Kw** 38CKC048-30, 31, 51, 61, 62 Outdoor Section With CD5AA048 Indoor Section continued 54.3 26.2...
  • Page 24 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 38CKC060-30, 31, 51, 52, 61, 62 Outdoor Section With CC5A/CD5AW060 Indoor Section 66.3 32.0...
  • Page 25 Condenser only ratings* CONDENSER ENTERING AIR TEMPERATURES °F °F 38CKC018-30, 33 17.6 16.2 14.7 13.4 12.0 10.7 9.52 8.35 1.37 1.49 1.58 1.66 1.73 1.77 1.80 1.82 75.6 86.1 96.4 106.0 116.0 126.0 136.0 146.0 19.6 18.1 16.6 15.1 13.6 12.3 10.9 9.68...
  • Page 26 Condenser only ratings* continued CONDENSER ENTERING AIR TEMPERATURES °F °F 38CKC036-30, 31, 34, 51, 53, 61 32.1 30.5 28.9 27.2 25.5 23.7 21.8 19.9 2.33 2.57 2.84 3.11 3.40 3.68 3.95 4.21 78.6 89.0 99.3 109.0 120.0 129.0 139.0 149.0 35.2 33.5 31.8...
  • Page 27 Condenser only ratings* continued CONDENSER ENTERING AIR TEMPERATURES °F °F 38CKC060-30, 31, 51, 52, 61, 62 52.8 50.6 48.2 45.8 43.3 40.6 37.9 35.2 3.87 4.27 4.73 5.23 5.78 6.37 6.99 7.63 75.7 86.2 96.6 107.0 117.0 127.0 137.0 147.0 57.8 55.4 52.9...
  • Page 28: Air Conditioner

    Indianapolis, IN 46231 11-99 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 28 Catalog No. 523-780 Printed in U.S.A. PC 101 Form 38CKC-4PD Replaces: 38CKC-3PD 3a 1a 2a...