Carrier 50HJQ004-016 Product Data page 130

Single-package rooftop standard and high efficiency heat pump units
Table of Contents

Advertisement

VOLTAGE
VOLTAGE
VOLTAGE
VOLTAGE
VOLTAGE
VOLTAGE
UNIT
UNIT
UNIT
RANGE
RANGE
RANGE
(3 PH 60
(3 PH, 60
(3 PH, 60
50HJQ
50HJQ
50HJQ
Hz)
Hz)
)
Min
Min
Max
Max
208/230
208/230
187
187
253
253
014
014
460
460
414
414
508
508
575
575
518
518
632
632
208/230
208/230
187
187
253
253
016
016
460
460
414
414
508
508
575
575
518
518
632
632
LEGEND
FLA
— Full Load Amps
HACR —
Heating, Air Conditioning and Refrigeration
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
NEC
— National Electrical Code
RLA
— Rated Load Amps
*Heater capacity (kW) is based on heater voltage of 208 v, 240 v, 480 v
and 600 v. If power distribution voltage to unit varies from rated heater
voltage, heater kW will vary accordingly.
†Fuse or HACR circuit breaker. This is the maximum size permissible;
smaller fuse size may be used where conditions permit.
NOTES:
1. In compliance with NEC requirements for multimotor and combination
load equipment (refer to NEC Articles 430 and 440), the overcurrent
protective device for the unit shall be fuse or HACR breaker. The
Canadian units may be fuse or circuit breaker.
2. MCA calculation for units with electric heaters over 50 kW
= (1.25 x IFM amps) + (1.00 x heater FLA).
OUTDOOR
OUTDOOR
OUTDOOR
COMPRESSOR
COMPRESSOR
COMPRESSOR
FAN
FAN
FAN
N
No. 1
No. 1
1
N
No. 2
No. 2
2
MOTOR
MOTOR
FLA
FLA
RLA
RLA
LRA
LRA
RLA
RLA
LRA
LRA
Qty
Qty
(
(ea)
39 7
39.7
228
228
3
3
1.7
1 7
19 9
19.9
114
114
3
3
0 8
0.8
16.0
16 0
91
91
3
3
0 75
0.75
28.2
28 2
160
160
28.2
28 2
160
160
3
3
1 7
1.7
14.1
14 1
80
80
14 1
14.1
80
80
3
3
0.8
0 8
11 3
11.3
64
64
11.3
11 3
64
64
3
3
0 75
0.75
50HJQ014,016
INDOOR FAN
INDOOR FAN
INDOOR FAN
POWER
POWER
POWER
MOTOR
MOTOR
MOTOR
EXHAUST
EXHAUST
EXHAUST
Hp
Hp
FLA
FLA
FLA
FLA
LRA
LRA
)
3 7
3.7
10.5/10.5
10 5/10 5
4.6
4 6
18 8
18.8
3 7
3.7
4 8
4.8
2 3
2.3
6 0
6.0
3.0
3 0
3 4
3.4
2.1
2 1
4.8
4 8
5
5
15 8/158
15.8/158
4.6
4.6
18.8
18.8
5
5
7 9
7.9
2.3
2.3
6.0
6.0
5
5
6.0
6 0
2.1
2 1
4 8
4.8
130
ELECTRIC
ELECTRIC
ELECTRIC
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
HEAT*
HEAT*
HEAT*
HEAT
FLA
FLA
kW
kW
MCA
MCA
MOCP†
MOCP†
—/—
—/—
65/ 65
100/100
39/ 45
14/19
114/122
125/150
72/ 92
26/34
155/168
175/175
117/135
42/56
211/200
225/225
—/—
—/—
70/ 70
100/100
39/ 45
14/19
119/126
125/150
72/ 82
26/34
159/173
175/175
117/135
42/56
216/205
225/225
32
50
18
15
54
60
39
32
81
90
66
55
98
110
34
50
18
15
57
70
39
32
83
90
66
55
100
110
26
40
37
37
72
80
28
40
37
37
75
80
—/—
—/—
84/ 84
110/110
72/ 82
26/34
174/187
175/200
117/135
42/56
231/219
250/225
—/—
—/—
89/ 89
110/110
72/ 82
26/34
179/191
200/200
117/135
42/56
235/224
250/225
42
50
39
32
91
100
66
55
108
110
44
50
39
32
93
100
66
55
110
125
34
40
50
50
96
100
36
45
50
50
98
100
DISCONNECT
DISCONNECT
DISCONNECT
SIZING
SIZING
SIZING
SIZING
RLA
RLA
LRA
LRA
64/ 64
64/ 64
387/387
387/387
94/107
147/167
69/ 69
69/ 69
406/406
406/406
100/112
152/173
31
31
189
189
50
82
34
34
195
195
53
84
26
91
91
47
28
96
96
50
89/ 89
101/112
499/485
499/485
153/173
94/ 94
106/118
518/504
518/504
158/179
44
54
238
238
85
47
57
244
244
88
35
165
165
64
38
169
169
67