This unit is equipped with an in-
terrupted ignition electronic con-
trol. If the main burner does not
ignite within 30 sec from the call
for heat, the control will lock out.
The red button on top of the con-
trol must be depressed for 3 sec in
order to reset the control. The con-
trol CANNOT be reset from the
room thermostat.
HEATING
Preparing Furnace For
Operation
Before attempting to put your fur-
nace into operation for the heating
season, you should perform the fol-
lowing procedures.
WARNING
!
If you do not follow these
instructions exactly, a fire
or explosion may result
causing property damage,
personal injury, or loss of
life.
1. Open all warm air registers and
make sure that all return-air
grilles are unobstructed.
2. If a humidifier is installed with
your system, open the water sup-
ply valve.
3. Set the thermostat to its lowest
setting.
4. Turn on electric power to the fur-
nace.
5. Open the oil supply valve.
6. Check all connections to ensure
there are no leaks.

Lighting Your Furnace

CAUTION
!
This furnace is equipped
with an interrupted type
electronic ignition system.
DO
NOT
ATTEMPT
LIGHT WITH A MATCH.
DANGER!
!
HIGH VOLTAGE AT IGNI-
TOR.
1. This appliance is equipped with
an ignition device which auto-
matically lights the burner. Do
NOT try to light the burner by
hand.
2. After preparing the furnace for
heating operation (See previous
section.) and checking for proper
oil supply, proceed as follows.
3. For a heating/cooling system, set
the thermostat to HEAT and the
fan to AUTO. Set the thermostat
to the desired room temperature
and turn on the electrical power
to the furnace.
4. The burner should light and the
system should be controlled by
the thermostat.
Turning Off Your
Furnace
Follow these simple procedures to
put your furnace into retirement for
the summer.
1. Set the thermostat to the lowest
setting.
2. Turn off all electrical power to
the appliance.
3. Turn the oil supply off.
4. If applicable, turn off water sup-
ply to humidifier.
5. If furnace blower will be neces-
sary for cooling system, remem-
ber to turn electrical power back
on when needed for air condi-
tioning.
MAINTAINING
YOUR UNIT
In order to keep your furnace run-
ning properly and at the efficiency
for which it was designed, the fur-
nace MUST be inspected and ser-
TO
viced once a year. Lack of yearly
service could lead to poor furnace
performance and damage to the
furnace.
Here are the things you should do
and have your service technician do
for you.
Homeowner:
1. Inspect and clean filter.
2. Make sure the following areas
are clear:
3. Set up yearly service.
Technician:
Minimum yearly service should in-
clude the following:
1. Check flue and secondary tube
passage ways including chimney
— clean if necessary.
2. Change oil filter.
3. Change nozzle.
4. Check and adjust combustion
and draft.
NOTE : Before you start, turn off all
electrical power to unit and turn
thermostat to OFF.
Filters
A filter is supplied with the furnace.
It is NECESSARY THAT ALL
FURNACES
WITH A FILTER.
If a different type of filter is used, it
must be an equivalent high airflow
capacity.
5
A. Outlet and return registers.
B. Air openings to furnace and
furnace area.
C. Chimney or flue exhaust.
BE