Return Air Temperature; Minimum Clearances To Combustible Materials - Bryant LEGACY 912SA Product Data

92.1 afue legacy line single-stage 4-way multipoise condensing gas furnace
Hide thumbs Also See for LEGACY 912SA:
Table of Contents

Advertisement

This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C)
db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

Front (Combustion air openings in furnace and in structure)
Required for service**
All Sides of Supply Plenum**
Top of Furnace
* Recommended
**Consult your local building codes
COMBUSTION- - AIR PIPE FOR NON- -DIRECT (1- -PIPE) VENT APPLICATION

RETURN AIR TEMPERATURE

SUPPLY AIR
POSITION
Rear
Sides
Vent
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
MITERED RADIUS
PVC 90° ELBOW
NOTE: See Installation Instructions for specific venting configurations.
CLEARANCE
0 (0 mm)
1 in. (25 mm)
24 in. (610 mm)*
1 in. (25 mm)
0 (0 mm)
0 (0 mm)
1 in. (25 mm)
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE
12" (300 mm) MINIMUM
11
80
/ 27˚C
60
/ 16˚C
A10490
A12376