Buttons Int10, Int11, Tin1, In0, In1, Reset (Jp: 7, 12, 14, 16, 20, 23) - Fujitsu FLASH-CAN-64P-350-PMC User Manual

F²mc-16lx/fx family
Table of Contents

Advertisement

4.13 Buttons INT10, INT11, TIN1, IN0, IN1, Reset (JP: 7, 12, 14, 16, 20, 23)

JP7:
One Button can be used for manually reset
JP12, JP14: Two push buttons can be used to trigger the ext. interrupts INT10 and INT11
JP16:
One button can be used as trigger-input for the Reload-Timer1 (TIN1)
JP20, JP23: Two push buttons can be used for input at Input-Capture 0 / 1 (IN0, IN1)
Jumper
Setting
JP7 (Reset)
JP12 (INT10)
JP14 (INT11)
JP16 (TIN1)
JP20 (IN0)
JP23 (IN1)
Default: JP7, JP12, JP14, JP16, JP20, JP23 =closed
By default, INT10, INT11, TIN1, IN0, IN1
are connected to the Push buttons.
UG-960008-10
FLASH-CAN-64P-350-PMC
Chapter 4 Jumpers and Switches
Description
1-2
Reset is triggered immediately
2-3
Reset is triggered delayed
Open
no connection
Closed
INT10 is connected to Push-button "INT10"
Open
no connection to INT10
Closed
INT11 is connected to Push-button "INT11"
Open
no connection to INT11
Closed
TIN1 is connected to Push-button "TIN1"
Open
no connection to TIN1
Closed
IN0 is connected to Push-button "IN0"
Open
no connection to IN0
Closed
IN1 is connected to Push-button "IN1"
Open
no connection to IN1
and