HEATING SPECIFICATIONS
Model: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1
Conditions: 1400 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
capacity
°F.
btuh
c.o.p.
65
51.54
4.44
60
48.79
4.28
55
45.92
4.11
50
42.93
3.92
45
39.73
3.70
40
36.90
3.50
35
34.03
3.30
30
34.27
3.26
25
31.63
3.08
20
29.12
2.90
15
26.48
2.70
10
23.76
2.48
5
21.07
2.25
0
18.37
2.01
-5
15.68
1.76
-10
12.84
1.48
*To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU)
Capacity of Unit*
With KW of Auxiliary heat
4.8
9.6
14.4
67.92
84.30
100.68
117.07
65.17
81.55
97.94
114.32
62.30
78.68
95.07
111.45
59.31
75.69
92.07
108.46
56.11
72.49
88.88
105.26
53.28
69.66
86.05
102.43
50.41
66.79
83.18
50.65
67.03
83.41
48.01
64.39
80.77
45.50
61.89
78.27
42.86
59.25
75.63
40.14
56.52
72.91
37.45
53.83
70.21
34.75
51.13
67.52
32.06
48.44
64.82
29.22
45.61
61.99
Model: SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1
Conditions: 1850 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
capacity
°F.
btuh
c.o.p.
65
71.65
4.34
60
67.83
4.19
55
63.84
4.03
50
59.68
3.85
45
55.23
3.64
40
51.30
3.45
35
47.31
3.26
30
47.86
3.17
25
44.17
2.99
20
40.68
2.83
15
36.99
2.63
10
33.19
2.43
5
29.42
2.21
0
25.66
1.98
-5
21.90
1.74
-10
17.94
1.46
Model: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1
Conditions: 1550 CFM Indoor Air @ 70°F DB
Basic Unit without
Outdoor
Auxiliary Heat
Ambient
capacity
°F.
btuh
19.2
65
57.82
60
54.74
55
51.52
50
48.16
45
44.57
40
41.40
35
38.18
99.56
30
36.62
99.79
25
33.80
97.15
20
31.12
94.65
15
28.30
92.01
89.29
10
25.39
5
22.51
86.59
83.90
0
19.63
-5
16.75
81.20
78.37
-10
13.72
Capacity of Unit*
With KW of Auxiliary heat
4.8
9.6
14.4
88.03
104.41
120.80
84.21
100.59
116.98
80.22
96.60
112.99
76.06
92.44
108.83
71.62
88.00
104.38
67.68
84.06
100.45
63.69
80.07
96.46
64.24
80.63
97.01
60.56
76.94
93.32
57.06
73.44
89.83
53.37
69.76
86.14
49.57
65.95
82.34
45.81
62.19
78.57
42.04
58.42
74.81
38.28
54.66
71.04
34.32
50.70
67.09
Capacity of Unit*
With KW of Auxiliary heat
c.o.p.
4.8
9.6
4.25
74.20
90.59
106.97
4.10
71.12
87.50
103.89
3.94
67.90
84.28
100.67
3.76
64.54
80.93
97.31
3.55
60.96
77.34
93.72
3.36
57.78
74.16
90.55
3.17
54.56
70.94
87.33
2.94
53.00
69.38
85.76
2.77
50.18
66.56
82.94
2.61
47.50
63.89
80.27
2.43
44.68
61.06
77.45
2.24
41.77
58.16
74.54
2.03
38.89
55.28
71.66
1.82
36.01
52.40
68.78
1.59
33.13
49.52
65.90
1.34
30.11
46.49
62.87
19.2
137.18
133.36
129.37
125.21
120.76
116.83
112.84
113.39
109.70
106.21
102.52
98.72
94.95
91.19
87.43
83.47
19.2
14.4
123.35
120.27
117.05
113.69
110.10
106.93
103.71
102.15
99.32
96.65
93.83
90.92
88.04
85.16
82.28
79.25
35