CAUTION:
the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup
and installation guide.
To remove the component:
CAUTION:
activity has stopped before removing the interconnect module.
IMPORTANT:
times.
Disconnect all cables from the component.
1.
Press the release tab.
2.
Open the handle.
3.
Remove the interconnect switch or Pass-Thru module.
4.
CAUTION:
more than one component or blank removed. When removing an active component, replace it
with a blank.
To replace the component, reverse the removal procedure.

Interconnect bay dividers

To remove the component:
Remove the interconnect switches and Pass-Thru modules
1.
page 40).
Remove the interconnect blanks
2.
Press the release tab.
3.
This procedure provides instructions for replacement of a failed part only. To change
To prevent data loss, redirect network activity or be sure that all critical network
An SFP port must be occupied by an SFP transceiver or an SFP dust cover at all
For best cooling practices, do not operate the enclosure for extended periods with
("Interconnect
("Interconnect switch or Pass-Thru
blank" on page 39).