TRAINING MANUAL
This chart shows the components and their times of operation in the various wash cycles.
The time estimates shown here are for the basic cycles before the fuzzy logic
adjustments are made. See the cycle and option chart on the following page.
• Be careful to avoid electric shock when disconnecting parts for troubleshooting.
• Most terminals in the steam washer have 120 Volts AC or DC on them,
sometimes even when the washer is off.
• The steam generator operates at a high temperature. Be careful when servicing it.
It can be drained in place by removing the drain cap, but have a hose or a big
towel ready to soak up the spillage.
WM0742HGA
PROGRAM CHART
BEFORE PERFORMING SERVICE
Page 18
WM0742HGA
TRAINING MANUAL