Diagnostic Tips - HP ProCurve 1700-8 Installation And Getting Started Manual

Hide thumbs Also See for ProCurve 1700-8:
Table of Contents

Advertisement

Diagnostic Tips:

Tip
Problem
Number
The switch's
power adapter
is not plugged
into an active
AC power
source, or the
power adapter
may have failed.
The network
connection is
not working
properly.
1. Verify the AC power adapter is plugged into an
active power source and to the switch. Make
sure these connections are snug.
2. Try power cycling the switch by unplugging
and plugging in the power.
3. If the Power LED is still not on, verify that the
AC power source works by plugging another
device into the outlet. Or try plugging the
switch into a different outlet.
If this condition persists, the switch's power
adapter may have failed. Call your ProCurve
Networking authorized network reseller, or use
the electronic support services from ProCurve
Networking to get assistance. See the Customer
Support/Warranty booklet for more information.
Try the following procedures:
• For the indicated port, verify that both ends of
the cabling, at the switch and the connected
device, are secure.
• Verify the connected device and switch are
both powered on and operating correctly.
• Verify the connected devices comply with the
appropriate IEEE 802.3 standard, including
transmission of the Link signal.
• If the other procedures don't resolve the prob-
lem, try using a different port or a different
cable.