Non-Hot-Plug Procedures
In order to remove or replace any non-hot-plug component, you must first power down the
server. The slimline drive procedure is the only procedure that you can perform without
removing the rear access panel.
This section describes the removal and replacement procedures for the following
non-hot-plug components:
•
Slimline drives
•
Front bezel
•
Power button/LED assembly
•
Processor air baffle
•
Processor power modules
•
Processors
•
Non-hot-plug PCI-X expansion boards
•
PCI-X expansion board basket
•
PCI-X Hot Plug Expansion board
•
SCSI cables
•
Front fan cage
•
Pass-through board
•
Removable media board
•
Rear fan cage
•
Battery-backed write cache assembly
•
SCSI backplane
•
System battery
•
System board
•
AC filter cable assembly
HP ProLiant DL580 Generation 2 Server Maintenance and Service Guide
WARNING: To reduce the risk of personal injury or damage to the equipment, the
installation of options other than hot-plug power devices should be performed only by
individuals who are qualified to service computer equipment and trained to deal with
products capable of producing hazardous energy levels.
Removal and Replacement Procedures
2-41