Toshiba Satellite U500 Maintenance Manual page 63

Hide thumbs Also See for Satellite U500:
Table of Contents

Advertisement

Procedure 4
Diagnostic Test Program Execution Check
The HDD/SSD test program is stored in the Diagnostics Disk. Perform all of the HDD/SSD
tests in the Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more
information about the HDD/SSD test program.
If an error is detected during the HDD/SSD test, an error code and status will be displayed.
Replace the HDD/SSD with a new one following the instructions in Chapter 4, Replacement
Procedures. The error codes and statuses are listed in Table 2-7. If an error code is not
generated or the problem still exists, go to Procedure 5.
Code
N0FH01
N0FH02
N0FH03
N0FH04
N0FH05
N0FH06
N0FH07
N0FH08
N0FH09
N0FH0A
N0FH0B
N0FH0C
N0FH0D
N0FH0E
Procedure 5
Connector Check and Replacement Check
The HDD/SSD may be disconnected, or the HDD/SSD or the main board may be damaged.
Disassemble the computer following the steps described in Chapter 4, Replacement
Procedures and perform the following checks:
Check 1
Make sure the HDD is firmly connected to CON6001 on the main board. Make
sure the SSD is firmly connected to CON6003 on the main board
Satellite M500/M505/M507 Maintenance Manual [CONFIDENTIAL]
Table 2-4 HDD/SSD error code and status
Can't Detect HDD when Boot Up/Detect wrong model name lf HD
HDD ATA/100 check error
HDD Firmware version error
Shipping HDD restore ERROR
Shipping OS has been booted
Shipping OS version error
shipping OS boot table error
2 Troubleshooting Procedures
Status
HDD Data Error
HDD Type error
Hmonitor test fail
HDD Heating test Fail
RAID function error
2nd HDD function error
SSD function error
2-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Portege m900dDynabook

Table of Contents