How To Care For Your Furnace; Gas Conversion Kits; Operate The Furnace; Caring For Your Furnace - Williams 4505622A Owner's Manual

Gravity vented floor furnace
Hide thumbs Also See for 4505622A:
Table of Contents

Advertisement

Caring for Your Furnace

How to Care For Your Furnace

Service, repair or maintenance of the furnace, vent or gas system
should only be attempted by a qualified service technician.
The burner and control of the furnace should be cleaned and
checked at least once each year by a qualified service technician.
If there is any indication that the furnace is operating improperly,
turn it off and have it checked immediately.
Lint and dust may be vacuumed from the interior of the furnace,
when it is cool, by removing the floor grille. The control and main
burner can be blown free of dust and lint with a vacuum cleaner.
WARNING: DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE IQUIDS OR VAPORS
NEAR THE FURNACE.
If the combustion chamber must be removed for servicing -
1. Turn the gas off at the main gas line shut-off valve.
2. Remove the floor grille and lift out the inner casing.
3. Lift the control end of the combustion chamber slightly, slide
the chamber toward the end of the cabinet about one inch and
then lift it out of 'the cabinet.

Gas Conversion Kits

Gas Conversion Kits
Natural Gas to L.P. Gas
Model
8953
8954
Gas Conversion kits
L.P. Gas to Natural Gas
Model
8955
8956
16
Description
450A Series
600A Series
Description
450A Series
600A Series
WARNING: DANGER OF BODILY INJURY OR
DEATH. DO NOT OPERATE THE FURNACE
WITH
A
BROKEN
OBSERVATION DOOR.
If the control and main burner assembly must be removed for
servicing -
1. Turn the gas off at the main gas line shut-off valve.
2. Disconnect the union in the gas supply line.
3. Remove the thermostat control wires from the gas control.
4. Remove the nuts that attach the gas control to the furnace
outer casing.
5. Remove the control assembly.
6. Remove the screw that attaches the control end of the burner
to the outer casing.
7. Slide the burner forward until the control end of the burner can
be dropped down and pull the burner out of the outer casing.
This should be done by a qualified service technician.
If the furnace will not be used for a long period of time, turn the
control knob to the "OFF" position and turn off the shut- off valve
in the gas line serving the furnace.