Fireplace Installation - MHSC SB50HB Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

SB50HB Series Woodburning Fireplace
LOCaTION SeLeCTION
Unpack and check the fireplace and chimney for damage. If any items have been damaged,
report this to your dealer. Before beginning the installation, be sure you have the proper parts
in sufficient quantity. Refer to Page 35 for proper identification of parts.
Do not substitute parts. Use only parts listed for use with the Model SB50HB fireplace.

FIrepLaCe INSTaLLaTION

1. Refer to Figure 1 for an example of a typical installation of the fireplace components.
. Be sure the location of the fireplace will provide the required clearances indicated by Figures
1, 3 & 4 and the minimum chimney air space clearance to combustibles of two inches.
3. Set the fireplace in the desired location and be sure it is securely supported and leveled.
Check the face of the fireplace with a carpenter's level and if it is not plumb; correct it by
placing shims under the edges of the fireplace.
4. Block in the fireplace to prevent any shifting of the firebox. Secure the fireplace with nails or
screws through the flanges located on each side of the fireplace. Do not enclose the fireplace
until the combustion air duct and chimney pipes are installed.
NOTe: Some local codes may require electrically grounding the fireplace and chimney.
CHIMNey INSTaLLaTION
In order to assure safe and satisfactory performance of the fireplace, it is very important to
properly install the chimney. This is an important part of the installation and the sections of this
manual pertaining to chimney installation should be reviewed very thoroughly.
For your safety, some of the important things to remember in regard to chimneys are listed
below:
1. Use only parts and accessories labeled for use with this fireplace.
. Use only undamaged parts and accessories.
3. Enclose the chimney where it passes through the living spaces to prevent contact with and
possible damage to the chimney.
4. Install firestop spacers at each ceiling level.
5. Install the proper chimney cap or chimney housing on the chimney to prevent the entry of
rain and debris into the chimney and to assure the proper venting of smoke.
6. Do not use more than four elbows in the chimney.
NOTe: To select the proper chimney height, refer to Figure 3. The flue outlet must be a minimum
of three feet above the highest point where the chimney penetrates the roof and a minimum
of two feet above all portions of the building within ten feet. If the chimney is to include elbows
to offset the chimney, refer to the Chimney Offset and Cap Installation section of this manual.
There must be at least two inches air space between all sections of the chimney and combus-
tible materials between floors.
16
FIrepLaCe INSTaLLaTION
87D0058

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents