FLOOr prOTeCTION

If this fireplace is installed on a combustible floor, the floor area 0 inches in front of, and 1 inches
either side of the fireplace opening must be protected by an insulating noncombustible hearth
extension. This hearth extension may be either minimum 6-inch thick stone or brick as shown by
Figure 10, or a locally constructed hearth equivalent.
A 0" x 74" piece of galvanized steel should be installed to cover the insulation before a finishing layer
of noncombustible material of stone, brick, tile, etc., is applied to finish the hearth extension.
The insulation used in the hearth extension should have a thermal conductivity (K factor) of 0.43.
If you do construct a hearth extension, be sure the insulation you use has enough compressive
strength to support the weight of the covering materials and persons standing on it, and insulating
qualities equal to or better than that described above.
Figure 10
Hearth
12" 
Min. 
Safety Strip is Re-
quired When Unit is
Placed on a Combus-
tible Floor or Platform
Figure 12
Top view
Fireplace and Hearth
extension
87D0058
12" 
Min. 
FP1
FP2221 
decorative hearth 
12" 
Screened Opening
74" 
Minimum Hearth Extension Dimensions
FP2222 
hearth extension 
Figure 11
20" 
Min. 
CauTION: Do not
place finishing materials
beyond these edges or
8" 
cover air inlets
Min. 
Brick or Stone Hearth
Extension - 74" Long
Min.
FP
12" 
20" 
SB50HB Series Woodburning Fireplace
CauTION:
Only brick or other noncombustible mate-
rial may be placed in front of, or in contact
with the black face of the fireplace.
FP2247
NOTe: A hearth extension placed on a
finishing front
combustible floor must be constructed
12/20/01 djt
with rigid insulation which has a mini-
mum "R" value of 1.16 or a "K" value of
0.43. The insulation must be covered
with a noncombustible covering such as
a tile, stone, marble, or a piece of 0.018
minimum sheet metal which is needed
to protect the insulation. Follow instruc-
tions provided with the for all other
specifications and directions for proper
installation of the fireplace and hearth
extension.
Screen
Rail
Hearth
FP1168