Amana GUI Installation Instructions Manual page 19

Gas-fired warm air furnace
Table of Contents

Advertisement

MANUAL
SHUT OFF VALVE
(UPSTREAM FROM
GROUND JOINT
PIPE UNION)
HEIGHT REQUIRED
BY LOCAL CODE
DRIP LEG
BURNERS
Figure 13 - General Furnace Layout
U
I
PFLOW
NSTALLATIONS
When the gas piping enters through the right side of the furnace, the
installer must supply the following fittings (starting from the gas valve):
90 degree elbows (2).
Close nipple.
Straight pipe to reach the exterior of the furnace
(Figures 14 & 16).
A ground joint union, drip leg, and manual shutoff valve must also be
supplied by the installer. In some cases, the installer may also need
to supply a transition piece from 1/2" to another pipe size.
When the gas piping enters through the left side of the furnace, the
installer must supply the following fittings (starting from the gas valve):
Straight pipe to reach the exterior of the furnace (Figures 15
& 17).
A ground joint union, drip leg, and manual shutoff valve must
also be supplied by the installer. In some cases, the installer
may also need to supply a transition piece from 1/2 inch to
another pipe size.
Figure 14 - Gas Inlet Through Furnace Right Side
GAS VALVE
MANIFOLD
GROUND JOINT
PIPE UNION
(Upflow)
Figure 15 - Gas Inlet Through Furnace Left Side
Figure 16 - Gas Inlet Through Furnace Bottom Side
Figure 17 - Gas Inlet Through Furnace Top Side
C
I
OUNTERFLOW
NSTALLATIONS
When the gas piping enters through the left side of the furnace, the
installer must supply a straight pipe to reach the exterior of the fur-
nace (Figure 18).
Figure 18 - Gas Inlet Through Left Side
19
(Upflow)
(Upflow)
(Upflow)
(Counterflow)