WARNING
WARNING
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– What to do if you smell gas:
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING
Should overheating occur or the gas supply
fail to shut off, turn off the manual gas
control valve to the furnace before shutting
off the electrical supply.
THE INSTALLATION AND SERVICING OF THIS EQUIPMENT MUST BE PERFORMED BY QUALIFIED,
Due to policy of continual product improvement, the right is reserved to change specifications and design without notice.
June 1999 (2)
®
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
EXPERIENCED TECHNICIANS ONLY.
Fayetteville, TN 37334
GUC*, GUX*, GUD*,
Gas-Fired Warm Air Furnace
User's Information Manual
Affix this manual, Specification Sheet and
Installation Instructions adjacent to the furnace.
WARNING
To avoid death, personal injury or property
damage, do not use this furnace if any part
of the furnace has been under water.
Immediately call a qualified service
technician to inspect the furnace and to
replace any part of the control system and
any gas control having been under water.

Important Note To The Owner

It is important that you fill out the owner's registration card
and mail it today. This will assist Amana in contacting you
should any service or warranty information change in the
future. When filling in the registration card, be sure to
include the Model, Manufacturing and Serial Numbers, plus
the installation date. If the registration card cannot be
located, please call 1-800-843-0304 to register the furnace.
Your warranty certificate is also supplied with the unit. Read
the warranty carefully and note what is covered. Keep the
warranty certificate in a safe place, so you can find it, if
necessary.
Before using this manual, check the serial plate for proper
model identification.
Amana
GDC*, GDC*
10318817

Advertisement

loading

Summary of Contents for Amana GUC*

  • Page 1: Important Note To The Owner

    It is important that you fill out the owner’s registration card • Do not touch any electrical switch; do and mail it today. This will assist Amana in contacting you not use any phone in your building. should any service or warranty information change in the future.
  • Page 2: Table Of Contents

    Table of Contents Important Note To The Owner ........................... 1 I. General Information ............................. 3 II. Operation ..............................5 III. Maintenance ..............................8 IV. Inspection of Furnace (Qualified Servicer Only) ..................10 V. For More Information ..........................11 VI. Safety Labels .............................. 12 ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to Remember, it is your responsibility to install the...
  • Page 3: General Information

    WARNING I. General Information To avoid personal injury or fire, minimum This furnace is built to provide many years of safe and dependable service, providing it is properly installed and clearances to combustible surfaces must maintained. However, abuse and/or improper use can be followed.
  • Page 4 These flue gases may include carbon monoxide. To prevent possible death or personal injury due to asphyxiation, Amana Condensing WARNING Gas Fired Warm Air Furnaces must be Death or personal injury from asphyxiation Category IV vented.
  • Page 5: Operation

    The vent system must slope toward the furnace for drain- PROPANE FURNACES ONLY age of condensate. Provision must be made to drain the WARNING condensate and protect the condensate drain trap and drain line from freezing conditions. To avoid death, personal injury or property damage due to explosion or fire, install a WARNING gas detecting warning device.
  • Page 6 Cool/Heat 5. This furnace is equipped with an ignition device which Room Temperature Temperature automatically lights the burner. Do not try to light burner Thermostat Control Dial by hand. 6. White Rodgers Model 36E36 or 36E37 or Honeywell Model VR-8205: Turn the gas control knob clockwise to the OFF position for either the White Rodgers gas valve (Figure 4) or the Honeywell gas valve (Figure White Rodgers Model 36E22 or 36E23: Push the...
  • Page 7 Main Redundant Solenoid Solenoid INLET OUTLET ON/Off Switch Inlet Pressure Tap Outlet Pressure Tap Main Regulator (Side of Valve) (Side of Valve) Adjust Flame Roll-Out Figure 6 Protection White Rodgers Device Model 36E22 or 36E23 ROLL-OUT PROTECTION DEVICE Figure 8 If flames from the burners are not properly drawn into the Roll-Out Protection Device - Counterflow heat exchanger, a flame roll-out limit switch will open...
  • Page 8: Maintenance

    RESET AFTER CONTROL LOCK-OUT If ignition has not been achieved for any reason after three Horizontal Counterflow (GDC and GCD) and Horizontal Right (GDC) Left Air Discharge ignition cycles, the electronic control module will lock-out (GDC) Air Discharge the furnace. Ignition is no longer attempted. The control's diagnostic light will then repeatedly flash once and then pause.
  • Page 9 sibility to keep air filters clean. NOTE: Dirty filters are the FILTER CLEANING AND REPLACING most common cause of inadequate heating or cooling Use a vacuum cleaner to clean out the blower area and the performance. adjacent area of the return air duct. Wash, rinse, and dry a permanent filter.
  • Page 10: Inspection Of Furnace (Qualified Servicer Only)

    The filters should be inspected and cleaned or changed AIR CIRCULATING BLOWER MOTOR LUBRICATION every two months or as required. In some installations, the The air circulation blower motor bearings are permanently filters can be inspected and cleaned or changed after lubricated.
  • Page 11: For More Information

    V. For More Information Most questions can be answered by the local Amana dealer. Check with dealer first if needing any further information regarding the operation, maintenance, or service of the furnace. If you have any matters that are not resolved locally, or for more information on other heating and cooling products or...
  • Page 12: Safety Labels

    VI. Safety Labels NOTE: If safety labels are missing or illegible, contact the installing dealer or Amana Customer Service Department for ordering information. THIS COMPARTMENT MUST BE CE COMPARTIMENT DOIT RESTER W ARNING: AVERTISSEMENT: CLOSED EXCEPT WHEN SERVICING FERME, SAUF POUR L'ENTRETIEN...

This manual is also suitable for:

Gux*Gdc*Gud*